Cabinet Front View
Electrical Requirements
120volt
grounded outlet
(or located in adjacent cabinet)
Warming drawer cutouts
Toe kick
A
B
2¹/₂" (6.4 cm) min.
9¹/₈" (23.2 cm)
2¹/₂" (6.4 cm) min.
9¹/₈" (23.2 cm)
Recommended 4¹/₄" (10.8 cm) Minimum 1" (2.5 cm)
4" (10.2 cm)
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
IMPORTANT: The warming drawer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
WARMING | CUTOUT | MIN. CABINET |
DRAWER SIZE | WIDTH (A) | WIDTH (B) |
|
|
|
24" (61 cm) | 22¹⁄₂" (57.1 cm) | 24" (61 cm) |
|
|
|
27" (68.6 cm) | 25¹⁄₂" (64.8 cm) | 27" (68.6 cm) |
|
|
|
30" (76.2 cm) | 28¹⁄₂" (72.4 cm) | 30" (76.2 cm) |
|
|
|
Warming drawer can be installed as an indoor single or double installation or installed under a single oven. Two warming drawers under a single oven are shown.
NOTE: The warming drawer cannot be leveled after being installed.
For outdoor installation follow the cutout dimensions above. Install the outdoor warming drawer in a permanent fixture.
Custom Wood Drawer Front
If you plan to install a custom wood panel to match your cabinets, we recommend consulting a qualified cabinetmaker or carpenter. The back of the wood panel must be sealed to avoid moisture damage.
A copy of the above code standards can be obtained from:
National Fire Protection Association One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road Cleveland, OH
■A 120 volt, 60 Hz., AC only,
■The model/serial rating plate is located above the
A
A. Model/serial number plate
3