Flexible metal appliance connector: If local codes permit, a new CSA
shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa).
Line pressure testing at 1/2 psi gauge (3.5 kPa) [14" (35.6 cm) WCP] or lower — The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of that system at test pressures equal to or less than
1/2 psig (3.5 kPa).
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect
Rigid pipe connection: Requires a combination of pipe fittings to obtain an
Shutoff valve: The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room as the range and should be in a location that allows ease of opening and closing. The valve is for turning on or shutting off gas to the range. Do not block access to shutoff valve.
manual shutoff valve
“open” position
to range
gas supply
Now start…
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1.Do not use oven door handle to lift or move the range.
2.Remove oven racks and parts package from inside oven. Remove shipping materials, tape and protective film from range.
3.Keep cardboard shipping base under range to prevent damage to floor covering.
Reconnect the
Failure to follow these instructions can result in death or serious burns to children and adults.
Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type floor covering.
4.Use the
Depending on the thickness of your flooring, longer screws may be needed to anchor the bracket to the sub
floor. Longer screws are available from your local hardware store.
5.Check that range is still on cardboard shipping base to protect floor
Pressure regulator: The gas pressure regulator supplied with this range must be used. The inlet pressure to the regulator should be as follows for proper operation:
L.P. GAS:
Minimum pressure:
11 inches (27.9 cm) WCP Maximum pressure:
14 inches (35.6 cm) WCP
NATURAL GAS:
Minimum pressure:
5 inches (12.7 cm) WCP Maximum pressure:
14 inches (35.6 cm) WCP
Contact local gas supplier if you are not sure about the inlet pressure.
Line pressure testing above 1/2 psi gauge (3.5 kPa) [14" (35.6 cm) WCP] — The range and its individual manual
cardboard shipping base
covering. Move range close to final location.
6.Remove cardboard shipping base from under range. Open broiler door. Use a 3/8" drive ratchet to lower rear leveling legs
legs
rear leveling leg