6.Insert one of the #8 x ³⁄₄"
#6 - 32 x ¹⁄₄"
A B C
A. Hole for #8 x ³⁄₄"
B. Threaded hole
C. #6 - 32 x ¹⁄₄"
7.Repeat for
8.Insert foam seal behind the top of the lower window sash and against the glass of the upper window.
9.Place
10.Use a ³⁄₃₂" drill bit to drill a starter hole through the hole in the bracket and into the window sash.
11.Attach
#8 x ³⁄₄"
B
A C
A. Window lock bracket
B. Foam seal
C. Upper window glass
1.Insert cabinet into the framed wall opening.
The top of the cabinet should extend ¹⁄₂" (13 mm) into the room. If there is trim, the cabinet should extend ¹⁄₂" (13 mm) past the trim.
B
A
2.Use a level to check that cabinet is level side to side.
A
A.Level
3.Check that air conditioner cabinet is tilted to the outside so that water will run to the outside.
4.Reuse the insulation to seal opening between cabinet and frame.
5.Use existing holes and 6 - #8 x ¹⁄₂" wood screws (not provided) to attach cabinet to frame.
NOTE: Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and air conditioner.
6.Caulk all outside wall openings around cabinet.
Complete Installation
NOTE: Handle air conditioner gently.
1.Make sure the free end of the ground wire is outside of the cabinet.
WARNING
Excessive Weight Hazard
Use two or more people to move and install air conditioner.
Failure to do so can result in back or other injury.
2.Insert air conditioner into cabinet.
WARNING
Electrical Shock Hazard
Connect green ground wire to ground screw.
Failure to do so can result in death or electrical shock.
3.Connect green ground wire to cabinet base with ground screw. Position ground wire pointing straight up. Put excess ground wire between coil and air conditioner cabinet.
A
+
A. ¹⁄₂" (13 mm) extending into room | + | B |
| ||
B. Trim | A. Green ground wire |
|
|
| |
| B. Ground screw |
|
8