Now start...
with range in kitchen.
1 n
Remove racks and other parts from inside oven.
2.
Floor Damage
Contact a qualified floor covering installer for the best procedure to drill mounting holes through your type of floor covering.
Before moving range across floor, check that range is on shipping base or slide range onto cardboard or hardboard.
Failure to follow these instructions may result in damage to floor covering.
Fire Hazard
Do Not make connection too tight. The regulator is die cast.
Overtightening may crack the regulator, resulting in a gas leak and possible fire or explosion.
All connections must be wrench-tightened.
flexible connector
l/2” nipple
l/2” nipple
Place one foot on the shipping base. Tilt range forward slightly to free rear legs. Gently lower range to floor. Tilt range backwards until legs are free.
3 1
Remove shipping materials, tape and protective film from range. Do Not remove cardboard shipping base at this time.
4.
Lower leveling legs approximately l/4 inch or to a point where the range base does not touch the floor.
l To prevent tipping, install range anti-tip bracket.
l Save these Installation Instructions. If range is moved to a new location, the anti-tip bracket must be removed and reinstalled in the new location.
5
The %-tip bracket must be installed. Anti-tip bracket may be fastened to the floor under the range or to the wall behind range.
centerline
!
!
To install anti-tip bracket on wall:
. Measure and mark a line at the center of the cabinet opening on the rear wall. Measure and mark lines
12-13/16” and 13-15/16”from either the left (shown) or right side of the centerline on the rear wall. Measure and mark on the rear wall a line 3/8” from the floor.
To install anti-tip bracket on floor:
lMeasure and mark a line in the center of the cabinet opening on the floor. Measure and mark lines 12-l 3/l 6” and 13-l 5/l 6” from either the left (shown) or right side of the centerline on the floor. Measure and mark on the floor 1” from the rear wall.
Note: If there is a cabinet on only one side, the anti-tip bracket must be installed against the cabinet, using the measurements given.
6
To m:unt anti-tip
bracket to wood floor or wall, drill l/8” holes at two mounting screw locations where the two are crossed by the third line.
To mount anti-tip bracket to concrete or ceramic floor or wall, use a masonry drill bit to drill l/4” holes at each mounting screw location. Tap plastic anchors into mounting holes in floor or wall with hammer.
7
Line:p holes in anti-tip bracket with holes in floor or wall. Use the mounting screws provided to fasten the anti-tip bracket to floor or wall.
8 n
Move range close to final position. Remove shipping base, cardboard or hardboard from under the range. Plug power supply cord into grounded outlet.
anti-tip brat ket
Carefully move range into final position. Open broiler drawer. Look under range. (A flashlight may be needed.) Check that the anti-tip bracket overlaps range base. If anti-tip bracket does not overlap base, remove range and reposition bracket to insure that range base will fit properly under bracket.
10.
If installing the range in a mobile home, you MUSTsecure the range to the floor, Any method of securing the range is adequate as long as it conforms to the standards listed in the Mobile home installation instructions, Panel A.
Place level on rack first side to side; then front to back. If the range is not level at the front, adjust the legs. If rear of range needs more than l/8” adjustment, add shims under anti-tip bracket. Close broiler drawer.
Note: Oven must be level for satisfactory baking conditions.
I | l/2” adapter | 112” adapter | I |
manual | | | pressure |
shutoff | | | regulator |
valve | | | |
12.
Lift up or remove maintop. Assemble the flexible connector from the gas supply pipe to the pressure regulator supply pipe in this order: manual shutoff valve, l/2” nipple, l/2” adapter, flexible connector, l/2” adapter, and l/2” nipple.
13.
Use pipe-joint compound made for use with L.P. gas to seal all gas connections If flexible connectors are used, be certain connectors are not kinked.
14.
Open the shutoff valve in the gas supply line. Wait a few minutes for gas to move through the gas line.
Fire Hazard
Do Not use an open flame to test for leaks from gas connections.
Checking for leaks with a flame may I result in a fire or explosion.
15.
Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off gas valve controls and adjust connections. Then check connections again. NEVERTEST FOR GAS LEAKSWITH A MATCH OR OTHERFLAME. Clean all detergent solution from range.
Initial lighting and gas flame adjustments depend on type of
system - electronic ignition or standing pilot. Raise cooktop and check which system is available. Continue installation, following steps under the heading for this range’s system.
Electronic Ignition System
Cooktop and oven burners use electronic ignitors in place of standing pilots. When the maintop control knob is turned to the “LITE”position, the system creates a spark to light the burner. This sparking continues until the control knob isturned to the desired setting. When the oven control is turned on, the ignitor will spark until oven burner pilot is lit.
urc4
16. 8
Check the operation of the maintop burners. Push in and turn
each control knob to@ ‘LITE” position. The flame should light within 4 seconds.
Do Not leave the knob in the “LlTE” position after burner lights.