Recommended installation spacing for cabinet installation
■The dimensions shown are for the recommended spacing.
■For cabinet installation, with a door, the minimum ventilation openings in the top are required.
7" (17.8 cm) | 7" (17.8 cm) |
9"
(22.9 cm)
4" | 31¹ " | 1" | 1" | 27" | 1" |
(10.2 cm) | (80.0 cm) | (2.5 cm) (2.5 cm) (68.6 cm) | (2.5 cm) |
Drain System
The washer can be installed using the standpipe drain system (floor or wall), the laundry tub drain system, or the floor drain system. Select the drain hose installation method you need. (See “Alternate Parts.”)
30" min. (76.2 cm)
1 | 2 |
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of 2 in. (5 cm). The minimum
The top of the standpipe must be at least 30 in. (76.2 cm) high and no higher than 96 in. (2.4 m) from the bottom of the washer.
Floor drain system (view 2)
The floor drain system requires a siphon break that may be purchased separately. (See “Alternate Parts.”)
The siphon break must be a minimum of 28 in. (71 cm) from the bottom of the washer. Additional hoses might be needed.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
■A
■This washer is equipped with a power supply cord having a 3 prong grounding plug.
■To minimize possible shock hazard, the cord must be plugged into a mating, 3 prong,
■If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
■Do not ground to a gas pipe.
■Check with a qualified electrician if you are not sure the washer is properly grounded.
■Do not have a fuse in the neutral or ground circuit.
| 28" min. |
30" min. | (71 cm) |
| |
(76.2 cm) |
|
1 | 2 |
Laundry tub drain system (view 1)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 30 in. (76.2 cm) above the floor.
2
1
3
4
1.3 prong grounding plug
2.3 prong
3.Grounding prong
4.Power supply cord