Cutout dimensions/requirements
25" (63.5 cm) countertop depth and 24" (61 cm) base cabinet depth, 36" (91.4 cm) countertop height
Product dimensions
18" (45.7 cm) upper side cabinet to countertop
4" (10.2 cm)
min. clearance from both sides of range to side wall or other combustible material.
13" (33 cm) max. upper cabinet depth
30" (76.2 cm) min. cabinet opening width
30" (76.2 cm) opening width
receptical or junction box – 8" (20.3 cm) to 22" (55.9 cm) from either cabinet,
7" (17.8 cm) max. from floor.
7/8" (2.2 cm) min. required between cutout and cabinet
door or hinge.
For minimum clearance to the top of the cooktop, see
NOTE.*
43" (109.2 cm) overall height
36" (91.4 cm) cooktop height with feet loosened
30"
(76.2 cm)
(70.5 cm)
depth
When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm) countertop — front of oven door protrudes
Anti-tip bracket:
*NOTE: 24" (61 cm) min. when bottom of wood or metal cabinet is protected by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) min. clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.
The floor
Electrical requirements
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to follow these instructions can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure range is grounded.
Do not have a fuse in the neutral or ground circuit.
A.When a
B.Wire sizes and connections must conform to the requirements of the National Electrical Code, ANSI/NFPA
70 — latest edition* or CSA Standard C22.1, Canadian Electrical Code, Part 1 — latest edition** and all local codes and ordinances for the kilowatt rating of the range.
Copies of the standards listed may be obtained from:
*National Fire Protection Association One Batterymarch Park
Quincy, Massachusetts 02269
**CSA International
8501 East Pleasant Valley Road Cleveland, Ohio
3