Cutout dimensions/requirements

25" (63.5 cm) countertop depth and 24" (61 cm) base cabinet depth, 36" (91.4 cm) countertop height

Product dimensions

18" (45.7 cm) upper side cabinet to countertop

4" (10.2 cm)

min. clearance from both sides of range to side wall or other combustible material.

13" (33 cm) max. upper cabinet depth

30" (76.2 cm) min. cabinet opening width

30" (76.2 cm) opening width

receptical or junction box – 8" (20.3 cm) to 22" (55.9 cm) from either cabinet,

7" (17.8 cm) max. from floor.

7/8" (2.2 cm) min. required between cutout and cabinet

door or hinge.

For minimum clearance to the top of the cooktop, see

NOTE.*

43" (109.2 cm) overall height

36" (91.4 cm) cooktop height with feet loosened

1-1/2 turns

30"

(76.2 cm)

27-3/4"width

(70.5 cm)

depth

When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm) countertop — front of oven door protrudes 1-7/8" (4.8 cm) beyond 24" (61 cm) base cabinet.

Anti-tip bracket:

*NOTE: 24" (61 cm) min. when bottom of wood or metal cabinet is protected by not less than 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.

30" (76.2 cm) min. clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet.

The floor anti-tip bracket must be installed. To install the anti-tip bracket shipped with the range, see Page 7 and the anti-tip bracket template.

Electrical requirements

WARNING

Electrical Shock Hazard

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure range is grounded.

Do not have a fuse in the neutral or ground circuit.

A.When a four-wire or three-wire, single- phase, 120/240-volt, 60-Hz, AC-only, electrical supply is available, a 50 amp maximum circuit protection is required (or, if specified on the model/serial rating plate, when a four- wire or three-wire, single-phase 120/208- volt, 60 Hz, AC-only electrical supply is available, a 40 amp maximum circuit protection is required), fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. The model/serial rating plate is located on the oven frame behind the drawer.

B.Wire sizes and connections must conform to the requirements of the National Electrical Code, ANSI/NFPA

70 — latest edition* or CSA Standard C22.1, Canadian Electrical Code, Part 1 — latest edition** and all local codes and ordinances for the kilowatt rating of the range.

Copies of the standards listed may be obtained from:

*National Fire Protection Association One Batterymarch Park

Quincy, Massachusetts 02269

**CSA International

8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575