30" (76.2 cm) Slide-in Electric Range
PRODUCT MODEL NUMBERS
GY397LXU GY399LXU
ELECTRICAL REQUIREMENTS
Electrical Connection
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
●Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial rating plate is located on the side of the oven frame behind the storage drawer or warming drawer panel. Refer to the figures in “Product Dimensions” in the “Location Requirements” section.
●This range is manufactured with the neutral terminal connected to the cabinet. Use a
Range Rating* |
| Specified Rating of |
|
| Power Supply Cord Kit |
|
| and Circuit Protection |
120/240 Volts | 120/208 Volts | Amps |
8.8 - 16.5 KW | 7.8 - 12.5 KW | 40 or 50** |
16.6 - 22.5 KW | 12.6 - 18.5 KW | 50 |
**The NEC calculated load is less than the total connected load listed
PRODUCT DIMENSIONS
A
F
E**
A. 30 | ³⁄₄ |
" (78.1 cm) |
B*
C
D
D. 29⁷⁄₈" (75.9 cm)
on the model/serial/rating plate.
**If connecting to a
●A circuit breaker is recommended.
●The range can be connected directly to the circuit breaker box (or fused disconnect) through flexible or nonmetallic sheathed, copper or aluminum cable. See the “Electrical Connection - U.S.A. Only” section.
●Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary.
●A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box).
●Wire sizes and connections must conform with the rating of the range.
●The wiring diagram is located on the back of the range or behind the storage drawer, in a clear plastic bag.
COUNTERTOP PREPARATION (for
The cooktop sides of the
If you have a square finish (flat) countertop and the opening width is 30" (76.2 cm), no countertop preparation is required.
Formed
Tile countertops may need trim cut back ³⁄₈" (1.0 cm) from each front corner and/or rounded edge flattened.
30"
(76.2 cm)³⁄₈"
(1.0 cm)
30 ¾"
(78.1 cm)
If countertop opening width is greater than 30" (76.2 cm), adjust the ³⁄₈" (1.0 cm) dimension.
Countertop must be level. Place level on countertop, first side to side, then front to back. If countertop is not level, range will not be level. Range must be level for satisfactory baking conditions.
B. 35³⁄₄" (90.8 cm) height to underside | E. 28⁵⁄₁₆" (71.9 cm) from |
of cooktop edge with leveling legs | handle to standoff at back |
screwed all the way in* | of range** |
C. Model/serial number plate (located | F. 23³⁄₄" (60.3 cm) |
behind the storage or warming | countertop notch to rear |
drawer on the side of the oven frame | of cooktop |
**Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm) countertop; front of oven door protrudes 2¹⁄₂" (6.4 cm) beyond 24"
(61.0 cm) base cabinet.
Page 1 of 2
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10430949A |
Instructions packed with product. Specifications subject to change without notice. | 5/11/12 |