12. TABLE FOR PROTECTION CIRCUIT ACTIONS

Symptom

Action

Indicator

Remedy

Reset

Excessive current flow

Current limiter operates

Peak indicator lights.

Remove overload.

Automatically reset if 4

due to overload

when load resistance is

 

 

(STEREO/PARALLEL) or

 

under 2.5 (STEREO/

 

 

8 (BTL) load is

 

PARALLEL) or 5

 

 

connected.

 

(BTL).

 

 

 

Short circuit (under 0.5 )

Current limiter operates.

Protection circuit

Check short circuit of

Switch power off, connect

 

Speaker loads cut by

indicator lights.

speakers and lines.

correct load, and switch

 

 

 

power on.

 

output relay.

 

 

 

Heat sink temperature rise

Speaker loads cut by

Protection circuit

Check ventilation and

Automatically reset if

 

output relay.

indicator lights.

overload.

temperature drops.

Unusual DC voltage output

Speaker loads cut by

Protection circuit

Contact your TOA

Switch power off, then

 

output relay.

indicator lights.

dealer.

remove cause.

13. APPEARANCE AND DIMENSIONS

Unit: mm

11

Page 11
Image 11
TOA Electronics IP-450D, IP-600D, IP-300D dimensions Table for Protection Circuit Actions, Appearance and Dimensions