Whirlpool MK2167 Installation Instructions, Tools and Parts, Required Cutout Dimensions

Models: MK2167

1 12
Download 12 pages 3.27 Kb
Page 2
Image 2
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Tools and Parts

Tools Needed

Required Cutout Dimensions

For minimum depth requirements, see chart.

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Measuring tape

Drill

Pencil

7/64" drill bit

Phillips screwdriver

Parts Supplied (not shown to scale

17" (43.2 cm)

min.

17¹⁄₈" (43.5 cm)

max.

3" Tools and Parts (7.6 cm) Tools Needed

6"

(15.2 cm)

23¹⁄₈" (58.7 cm)

1¹⁄₁₆"

(2.7 cm)

A

Required Cutout Dimensions 1¹⁄₁₆" Parts Supplied (not shown to scale (2.7 cm)

B

Rails (2)

Bottom duct

Trim kit frame

Short screws (14)

Long wood screws (6 - painted)

(11 + 3 extra)

(4 + 2 extra)

 

 

 

 

Location Requirements

The microwave oven may be installed over a built-in oven. If installing over a built-in oven, make sure there is a minimum of 3" (7.6 cm) between the top of the lower oven cutout and the microwave oven cutout floor.

The microwave oven may also be installed in a cabinet by itself (without a built-in oven below). For best usability, we recommend a minimum distance of 36" (91.4 cm) from the floor to the cutout floor.

Make sure the surrounding cabinetry has clearance to open and close freely. Allow a clearance of at least 1⁹⁄₁₆" (4.0 cm) below the cutout floor (3" [7.6 cm] for installation above a built-in oven), and a clearance of at least 2" (5.1 cm) above the cutout opening.

 

A

2"

2"

(5.1 cm)

(5.1 cm)

B

B

1⁹⁄₁₆"

3"

(4.0 cm)

(7.6 cm)

 

 

C

D

36"

(91.4 cm)

 

E

 

A. Upper cabinet

D. Lower cabinets

B. Microwave oven cutout

E. Floor

C. Lower oven cutout

 

DC

A.Trim kit frame overhang

B.Cutout for lower oven

C.Recommended region for receptacle location (no less than 6" [15.2 cm] to the right of cutout centerline)

D.Cutout centerline

Receptacle Location

Minimum Depth

Within recommended

18" (45.7 cm) with flush receptacle;

region

21" (53.2 cm) with non-flush receptacle

 

 

 

Outside recommended

19¹⁄₂" (49.5 cm) with flush receptacle;

region

22¹⁄₂" (57.2 cm) with non-flush

 

receptacle

 

 

NOTES:

Depth requirements depend upon receptacle and its location within or outside of recommended region. See illustration and chart above.

Height dimension is critical: 17" (43.2 cm) minimum, 17¹⁄₈" (43.5 cm) maximum.

Width measurement has ±1/16" (2 mm) tolerance.

3" (7.6 cm) minimum dimension is from lower oven cutout ceiling to microwave oven cutout floor.

Trim kit frame extends 1¹⁄₁₆" (2.7 cm) above and below the cutout opening.

2

Page 2
Image 2
Whirlpool MK2167 Installation Instructions, Tools and Parts, Required Cutout Dimensions, Location Requirements