Miele DA 429-4, DA 428-4 Warning and Safety instructions, Warning - danger of toxic fumes

Models: DA 428-4 EXT DA 429-4 DA 429-4 EXT DA 428-4

1 40
Download 40 pages 38.84 Kb
Page 6
Image 6
Warning - danger of toxic fumes

Warning and Safety instructions

￿Do not connect the appliance to the mains electricity supply via a multi-socket unit or an extension lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating).

Using at the same time as other heating appliances that depend on the air from the room

Warning - danger of toxic fumes

￿For appliances with an external fan motor fitted (...EXT models), the connection of the two units must be made using the connection cable and the plug connectors.

These models may only be combined with a Miele external motor.

￿This rangehood must not be installed and operated in mobile installations (e.g. on a ship).

￿In areas which may be subject to infestation by cockroaches or other vermin, pay particular attention to keeping the appliance and its surroundings in a clean condition at all times. Any damage which may be caused by cockroaches or other vermin will not be covered by the warranty.

￿Great care should be taken when using the rangehood at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room. Such appliances include gas, oil, wood or coal-fired boilers and heaters, continuous flow or other water heaters, gas cooktops or ovens which draw air in from the room and duct exhaust gases out through a chimney or extraction ducting.

When used in extraction mode, with or without an external motor fitted, the appliance draws air in from the room in which it is installed and from neighbouring rooms.

If there is insufficient air, an underpressure will occur. The heating appliance may be starved of oxygen, impairing combustion.

Harmful gases could be drawn out of the chimney or extraction ducting back into the room, with potentially fatal consequences.

6

Page 6
Image 6
Miele DA 429-4 EXT, DA 428-4 EXT Warning and Safety instructions, Warning - danger of toxic fumes