INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE HOMEOWNER.
HOMEOWNER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Wiring Diagrams are included in this package.
INSTALLATION
INSTRUCTIONS
FOR 30” EYELEVEL GAS RANGE
Before you begin, read the following instruc- tions completely and carefully. If followed, they
will simplify the installation job.
IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Input | ratings | shown | on the | rating | plate | [serial | tag1 | are | for | elevations | ||||
up to | 2.000 | feet. | For | elevations | above | 2,000 | feet, | ratings | should be | |||||
reduced | at | a rate | of | 4% | for | each | 1.000 | feet | above | sea | level. |
PROPER GAS SUPPLY
INSTALLATION REQUIREMENTS
This lnstallatlon must conform with the American Natlonal Stand-
ard, Natlonal Fuel Gas Code ANSI
MOBILE HOME INSTALLATION AEGIJIREMENTS ARE LISTED BELOW ON PAGE 4.
‘Copies of the standard
1.This range IS manufactured for use with NATURAL GAS. It can be converted for use on LP GAS. The rating plate lo- cated under the main top has the InformatIon on the type of gas this unit can be used with. When in doubt check with your local gas supplier.
2.Provide a gas supply line to the unit location. We suggest using a 74” rigid pipe, as smaller size pipe on long runs may
result in the gas supply not being sufflclent. Pipe joint
compounds resistant to the action of LP gas must be used.
3 The supply line should be equipped with a shutoff valve. This valve should always be located in the same room as the range and should be in a locatlon that allows ease of opening and closing. Do not block access to the shutoff valve.
4 If local codes permit, it is recommended that flexible
metal tubing
ciation, be used for connecting the appliance to the gas
supply line. [The gas valve connectlon will accept a 3%” male pipe thread.1
5.If rlgld pipe IS used as a gas supply line, a combination of pipe fittings must be used to obtain an
6.The gas pressure regulator on this model IS convertible and must be used. This regulator can be used on either NATURAL or LP gases. The pressure regulator has fixed outlet pressure at NATURAL and LP settings and these cannot be changed. The fixed outlet pressure on NATU- RAL gas setting is 4 inches W.C. On the LP gas setting the outlet pressure IS 10 inches W.C.
llsted above may be obtained from:
AMERICAN GAS ASSOCIATION
1515 Wilson Boulevard
Arlington, Virginia 22209
1