Surface Units and Reflector Bowls
Removing
Burn and Electrlcal Shock Hazard
Make sure all surface units are OFF before removlng surface units and reflector bowls. Failure to do so can result in burns or electrical shock.
1. Turn off ail surface units. | !. Lift the edge of the unit, opposite |
| the receptacle, just enough to |
| clear the element hold down cliF |
| and the reflector bowl. |
3.Pull the surface unit straight away from the receptacle.
4.Lift out the reflector bowl. See “Cleaning Chari” on page 21 tor cleaning instructions.
continued on next page
15