RANGE HOOD BLOWER

(TOP OF iiOODi

NOTE: Before reinstalling th e blower Assembly, check the damper for free operation. Open the damper blade and

check for any restrictions in the duct system. Check installation instructions for proper duct sizing.

Correct Blower orientation is Imperative. incorrect installation will drastically cut air flow and cause Blower to run at maximum RPM regardless of motor speed control setting.

VERTICAL DISCHARGE:

1.Figure 7 shows the proper Blower Assembly orientation for vertical discharge.

2.From the blower positron shown in Figure 7, lift the Blower Assembly vertically into mounting position.

3.The 3” blower discharge surface should now be flush agatnst top of hood. This will allow proner air flow from the blower through the top vent. (The wider 5” surface will be to the rear.)

HORIZONTAL

DISCHARGE VENT

(REAR OF HOOD)

HORIZONTAL DISCHARGE:

1Figure 8 shows the proper Blower Assembly orrentatron for horizontal discharge.

2From the Blower position shown in Figure 8, lift the blower Assembly vertically Into position.

3The 3” Blower discharge surface should now be flush against rear of hood. This will allow proper air flow from the Blower through the rear vent. (the wider 5” surface WIII be to the top.)

ORIENTATION

i/a

BLOWER 3lSCHARGE -

LOCATE AT DIS-

CHARGE VENT IN

TOP OF HOOD

,,,‘THlS SURFACE

TO REAR

Figure 7

VERTICAL DISCHARGE

THIS SURFACE TO TOP

CHARGE VENT

IN REAR OF HOOD

Figure 8

HORIZONTAL DISCHARGE

Page 3
Image 3
Whirlpool RH7330XL manual Vertical Discharge, Horizontal Discharge