5.For an easier installation, remove the filters and the Three assemblies shown in Fig. 9. This reduces the weight about 40% The blower cover and light frame assembly are held into place with thumb screws To remove the blower asembly. first unplug the blower supply cord from the junction box Remove the packrng screw from the blower retaining rod, then pull the blower retarnrng rod to one srde. freeing it from between the bumps on the blower housing

6.Remove screw holding junction box cover.

7.Remove proper electrical knockout. See Figure 1.

8.Remove proper venting knockout. See Fig. 1. NOTE: If horizontal discharge is selected, an additronal knockout In the blower cradle must be removed.

9.Attach the damper as shown in Figure 5 for vertical discharge or Fig. 6 for horizontal discharge.

10.Lift the hood into position. Mark location of four mounting holes.

11.Remove hood and start all four screws in center of narrow neck of keyhole slot marked on cabinet bottom.

12.Lift into position on four screws simultaneously feeding electrical wire through knockout.

13.Tighten screws to secure hood. Be sure screw head is in narrow neck of keyhole slot.

14.Install proper duct work

15.Complete electrical wiring In junction box according to the national Electrical Code and applicable Local Codes.

NOTE: This unit must be permanently grounded in accordance with the National Electrical Codeand applicable Local Codes.

16.Replace junction box cover.

17.Replace blower. Note different blower positions in Figure 7 for vertical venting and Figure 8 for horizontal venting.

18.Replace blower cover, light frame assembly and filters.

NOTE: It has been found that a large part of the energy loss of the average home is due to outside air infiltrating the structure. Seal around ductwork where it passes through outside walls or ceiling. Seal around electrical wiring also.

19.Be sure that damperwhich issuppliedwith this model is properly installed. (See Figures 3 8 4).

rKEYHOLE SLOT ‘\ IN CANOPY

yQAlN CA?

 

IF RAIN

CAP

HAS

 

A CAMPER,

REMOVE

I,

DAMPER

BLADE

(167666cm)

FROM

HOOD.

Figure 3

VERTICAL VENTING 2;’ x IO” RECTANGULAR

RAIN CAP iiAS

DAMFEQ, QEIMOVE

MPE-R BLADE

OM ~i000.

Figure 4

 

SCREW--!

 

 

(IN

INSTALLATION

 

 

Figure 2

PARTS BAG)

HORIZONTAL

VENTING

 

r

DAMPER BLADE

 

 

Figure 5

Figure

6

PRCIP 2

Page 2
Image 2
Whirlpool RH7330XL manual Horizontal, VERTICAL VENTING 2’ x IO” RECTANGULAR, Venting