1.Make a template or transfer measurements shown in Fig. 3 to cabinets or wall.

2.Cut holes to accomodate ventilating duct allowing W’ (.6 cm) clearance on all four sides for back vent. Allow J/4”(1.9 cm) clearance toward front for vertical vent. Allow %” (.6 cm) on other three sides for top vent.

3.Cut appropriate hole for electrical wiring.

4.Run wire through wall or cabinets according to National Electrical Code and Applicable local codes. (DO NOT turn power on until installation is complete.)

5.Remove blower housing and filters for easier installation. See exhaust unit assembly illustration on page 6.

6.Remove screw holding junction box cover.

7.Remove proper electrical knockout. See Figure 3.

8.Remove proper venting knockout. See Figure3. NOTE: If horizontal discharge is selected an additional knockout in the blower cradle must be removed.

9.Attach the damper as shown in Figure 5 for vertical discharge or Fig. 6 for horizontal discharge.

10.Lift the hood into position. Mark location of four mounting holes.

11.Remove hood and start all four screws in center of narrow neck of keyhole slot marked on cabinet bottom.

12.Lift the hood into position simultaneously feeding the electrical wire through the knockout. Follow applicable local codes and/or latest National Electrical Code for electrical connector to be used at field wiring entrance.

13.Tighten screws to secure hood. Be sure screw head is in narrow neck of keyhole slot.

14.Install proper duct work. See page 4

15.Complete electrical wiring in junction box according to the National Electrical Code and applicable Local Codes NOTE: This unit must be permanently grounded in accordance with the National Electrical Code and applicable Local codes.

16.Replace junction box cover.

17.Replace blower. Note different blower positions in Figure 5 for vertical venting and Figure 6 for horizontal venting. See Page 3 for correct blower installation.

18.Replace blower cover, light frame assembly and filters.

NOTE: It has been found that a large part of the energy loss of the average home is due to outside air infiltrating the structure. Seal around ductwork where it passes through outside walls or ceiling. Seal around electrical wiring also.

19.Be sure that damper which is supplied with this model is properly installed. (See Figures 1 8 2).

6-1

c5mf

FIG&E 5

FIGURE 6

 

Page 2

TRAIN CAP

IF RAIN CAP HAS

A CAMPER, REMOVE

DAMPEF) BLADE

FROM rCOO0

FIGURE 1

VERTICAL VENTING ,a

3%. x IO” RECTANGULAR

IF RAIN CAP HAS

A DAMPER. REMOVE

DAMPER BLAOE

FROM HOOD.

FIGURE 2

HORIZONTAL VENTING

FIGURE 4