TROUBLE SHOOTING PROCEDURE

lf entire unit is not working, proceed as follows:

1.Check circuit breaker box to insure that breaker for hood is not tripped.

2.Remove printed circuit board enclosure cover by removing two screws securing the cover. (See Figure I .)

CAUTION: SHOCK HAZARD

SOME CIRCUIT BOARD COMPONENTS (INCLUDING HEAT SINKS) ARE NOT ISOLATED FROM THE AC POWER LINE.

3.Disengage five pin connector from P. C. board and check for 115VAC (nominal) AC line voltage between the black wire socket (end socket) and white wire socket (center socket) by inserting VOM probes into sockets.

4.If voltage is not present, proceed as follows:

a.Turn off power at breaker box.

b.Check connections in rear power entry box. (See Fig. 1.)

(1)Push in filter retainmg tabs and remove filter from wiring compartment.

(2)Remove cover retaining screws and cover.

(3)Remove wiring box covers (2).

C.Check continuity of wires from wire nut connections to P. C. board sockets by inserting one

meter probe in wire nut connection and the other probe in respective socket connector.

d.Repair or replace as required, restore power to unit and again check for voltage at P. C. board connector.

5.If the fan or light still does not operate, proceed as follows:

a.With five pin connector plugged into board and light and/or fan turned on, check output of the red (light) and blue (fan) wires in the five pin connector by inserting one probe of the meter in

the backof

thesocket

at therespectivewireconnection

(redor

blue) andtheotherprobein

the

back of the socket at the black wire connection.

 

 

 

(1)Reading for red wire output should be 50-65 VAC if the light is on “Lo” or loo-125 VAC if the light is on “Hi”.

(2)Reading for blue wire output should be between 72 VAC and the line voltage reading, depending upon fan speed setting.

b.If output readings are correct, problem is in the wiring from plug to devices (fan and light) or in the devices themselves. (Bad socket or bulb and/or defective fan motor.)

C.If outputs are not correct, problem is in the circuit board or membrane switch. (See Page 2.)

CIRCUIT BOARD

ENCLOSURE

-,

FIVE

PIN

CONNECTOR

 

COVERMTG

SCREWS (2),

\

.y

TRIM

RETAINING

SCREWS (41,

FILTER RETAINING TABS (4) -J

COVER RETAINING SCREWS (2)

FIG. 1 INSIDE OF HOOD

A626-476

(1)

1-11-64

Page 7
Image 7
Whirlpool RH8930XLS manual Cover MTG, Cover Retaining Screws

RH8930XLS specifications

The Whirlpool RH8930XLS is a sophisticated and versatile tumble dryer, designed to provide optimal performance while catering to the needs of modern households. Known for its efficient drying capability, this model combines advanced technology with user-friendly features to ensure laundry is dried quickly and effectively.

One of the standout features of the RH8930XLS is its Heat Pump Technology. This innovative system not only reduces energy consumption but also allows the dryer to recycle hot air for maximum efficiency. This not only lowers utility bills but also ensures gentler drying that helps preserve the quality of fabrics over time. The Energy Efficiency rating is top-notch, making it an eco-friendly choice for conscious consumers.

The appliance is equipped with a substantial drum capacity, allowing users to dry large loads in one go. This capacity is particularly beneficial for families or households with frequent laundry needs, minimizing the number of cycles needed and thus saving time. The unique drum design also promotes better circulation of air, which results in more consistent drying throughout.

In terms of settings, the RH8930XLS offers multiple drying programs suited for various fabric types and load sizes. Users can select from options such as Delicates, Wool, and Cotton programs, each tailored to handle laundry with care. The inclusion of a sensor drying feature further enhances the dryer’s functionality by automatically detecting moisture levels in the clothes and adjusting drying times accordingly. This ensures garments are dried to perfection without the risk of over-drying.

Another notable characteristic of the Whirlpool RH8930XLS is its user-friendly interface. The intuitive control panel features a clear display and straightforward buttons that allow for easy program selection and monitoring. Additionally, the drying cycle can be customized with a delay-start option, providing the flexibility to fit laundry chores into a busy schedule.

Maintenance is made simple with the RH8930XLS as well. The dryer is designed with an easy-access filter, allowing users to clean it with minimal effort. This ensures optimal performance and longevity of the appliance.

Overall, the Whirlpool RH8930XLS combines cutting-edge technology, energy efficiency, and practicality, making it an excellent addition to any home seeking a reliable and effective tumble dryer.