RANGE HOOD BLOWER ORIENTATION
(TOP OF HOOD1
NOTE: Before reinstalling the blower Assembly, check the
damper for free operation. Open the damper blade and
check for any restrictions in the duct system. Check
installation instructions for proper duct sizing.
Correct Blower orientation is imperative. Incorrect tnstallatron will drastically cut atr flow and cause Blower to run at maximum RPM regardless of motor speed control setting.
BLOWER DISCHARGE - ‘LXATE AT OIS-
CHARGE VENT IN
TOP OF HOOD
,,/ THIS SURFACE
TO REAR
VERTICAL DISCHARGE:
1, Figure 7 shows the proper Blower Assembly ortentatton’ for vertical discharge.
2.From the blower position shown in Figure 7. lift the Blower Assembly verttcally Into mounting position.
3.The 3” blower drscharge surface should now be flush against top of hood. This will allow proper air flow from the blower through the top vent. (The wider 5” surface will be to the rear.)
HORIZONTAL
DISCHARGE VENT
(REAR OF HOOD)
HORIZONTAL DISCHARGE:
1.Figure 8 shows the proper Blower Assembly orientation for horizontal discharge.
2.From the Blower position shown in Figure 8. lift the blower Assembly vertrcally into position
3.The 3” Blower drscharge surface should now’ be flush against rear of hood. This will allow proper air flow from the Blower through the rear vent. (the wider 5” surface will be to the top.)
FIGURE 7
VERTtCAL DISCHARGE
THIS SURFACE TO TOI=
BLOWER DISCHARGE -
LOCATE AT DIS-
FIGURE 8
HORIZONTAL DISCHARGE
Page 3