1.Connect the appliance to the junction box
through flexible armoured or nonmetallic sheathed copper cable (with ground wire). A suitable strain relief must be provided at each end of the power supply cable (at appliance and at the junction box). See Figure 8.
2.This appliance is equipped with copper lead wires. If connection is made to aluminum house wiring, use only special connectors which are approved for joining copper and aluminum wires in accordance with the National Electrical Code and local codes and ordinances.
Electrical Ground is Required on This Appliance
Recommended
Electrical Connection and Groundrng Method
This appliance must be permanently grounded in accordance with the National Electrical Code and local codes and ordinances.
*Cold water pipe must have metal continuity to electrical ground and not be interrupted by plastic, rubber or other electrically insulating connectors (including water meter or pump) without adding a jumper wire to these connections.
C. INSTALLING AND LEVELING THE MICROWAVE OVEN.
1.Remove the screw from the upper left hand side of the microwave oven. See Figure
2.Screw the safety bracket to the back of the microwave with the screw removed in the previous step.
SCREW REMOVED FROM | / |
TO 20 AMP FUSED DISCONNECT
(WIRING DONE ACCORDING TO
NATIONAL ELECTRICAL CODE __
AND APPLICABLE LOCAL CODES)
RECEPTACLE7H
CONNECTION)
LEADING TO
SWITCHES
I | \GROUND | I |
I | SCREW | |
| I | |
I |
| I |
TERMINAL
ACCESS
COVER
Figure 9
3.Place the empty hood carton the top of the cooktop. Test the shelf hood for strength. If the mounting seems secure, proceed to the next step.
4.WARNING: THE WEIGHT OF THE MICROWAVE OVEN MAY EXCEED YOUR
LIFTING ABILITY. WE RECOMMEND ASSISTANCE.
Figure 8
1.Remove the terminal access cover. See Fig. 8.
2.Install a strain relief into the opening of the wire junction box. See Figure 8.
3.Connect the white and black wires of the power supply cable to the white and black wire leads inside the terminal access box. See Figure 8.
4.Connect the green ground wire from the power supply cable to the end of the green ground wire provided in the terminal access box. See Figure 8.
5.Replace the terminal access cover.
Alternate Grounding Method
If the recommended grounding method is impossible, permanently ground the appliance from the green ground wire (located in the terminal access box) to a grounded cold water pipe* using a
separate, green colored, insulated copper conductor of appropriate size (no. 16 minimum). THIS, HOWEVER, IS NOT RECOMMENDED. Do not ground to a gas supply pipe. Do not connect to electrical supply until appliance is permanently grounded.
SHELF HOOD | \yy##y‘Is | ||
| 7 I( | I |
|
|
|
|
HANGING ANGLE
SHELF
HOOD
BACK
LEVELING
BOLTS
Figure 10 w
Page 4