5. Connect ground wire

A

F

Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw.

6. Connect remaining wires

3-wire Power Supply Cord Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

B D E

A

CG F

A.3-wire receptacle (NEMA type 10-30R)

B.3-wire plug

C.Neutral prong

D.Spade terminals with upturned ends

E.3/4" (19 mm) UL listed strain relief

F.Ring terminals

G.Neutral (white or center wire)

3.Remove center screw

B

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

Remove center, silver-colored terminal block screw (B).

4. Connect neutral wire

B C

Connect neutral wire (white or center) (C) of power supply cord to center, silver-colored terminal block screw (B). Tighten screw.

5. Connect remaining wires

Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

8

Page 8
Image 8