VENTING

Venting Requirements

WARNING

Fire Hazard

use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.

Do not use plastic or metal foil vent.

Rigid metal vent:

Recommended for best drying performance and to avoid crushing and kinking.

Flexible metal vent: (Acceptable only if accessible to clean) Must be fully extended and supported in final dryer location.

Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install in enclosed walls, ceilings, or floors. The total length should not exceed 7 3/4 ft. (2.4 m).

NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review Vent system chart and if necessary, modify existing vent system to achieve best drying performance.

Exhaust hoods:

Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).

B

 

4"

C

A

(102 mm)

 

 

4"

 

2½"

(102 mm)

 

 

(64 mm)

 

 

4"

 

 

(102 mm)

 

 

Recommended styles:

 

Acceptable styles:

A. Louvered hood

 

C. Angled hood

B. Box hood

 

 

Elbows:

45° elbows provide better airflow than 90° elbows.

GoodBetter

Clamps:

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

See “Venting Kits" for more information.

12

Page 12
Image 12
Whirlpool W10096987A, W10097001A-SP Venting Requirements, Rigid metal vent, Exhaust hoods, Elbows, Clamps