14

Vent system chart

NOTE: Performance of rear exhaust to either side of the dryer is
equivalent to adding one elbow. To determine maximum exhaust
length, add one elbow to the chart.
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See “Determine vent path” in “Plan Vent System.” Avoid 90º
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
Install Leveling Legs
1. To protect the floor, use a large, flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer.
2. Firmly grasp the body of the dryer (not the top or console
panel). Gently lay the dryer on the cardboard. See illustration.
3. Examine the leveling legs. Find the diamond marking.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Check that the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible
gas line.
4. Once the exhaust vent connection is made, remove the
corner posts and cardboard.
Level Dryer
Check the levelness of the dryer by first placing a level on the top
of the dryer near the console.
Then, by placing a level in the crease on the side of the dryer
between the top of the dryer and the dryer cabinet, check the
levelness from front to back.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.
Number of
90º turns
or elbows
Type o f
vent Box or
Louvered
hoods
Angled
hoods
0 Rigid metal
Flexible metal 64 ft (20 m)
36 ft (11 m) 58 ft (17.7 m)
28 ft (8.5 m)
1 Rigid metal
Flexible metal 54 ft (16.5 m)
31 ft (9.4 m) 48 ft (14.6 m)
23 ft (7 m)
2 Rigid metal
Flexible metal 44 ft (13.4 m)
27 ft (8.2 m) 38 ft (11.6 m)
19 ft (5.8 m)
3 Rigid metal
Flexible metal 35 ft (10.7 m)
25 ft (7.6 m) 29 ft (8.8 m)
17 ft (5.2 m)
4 Rigid metal
Flexible metal 27 ft (8.2 m)
23 ft (7 m) 21 ft (6.4 m)
15 ft (4.6 m)
WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.