Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Additional spacing is required if you exhaust out the rear of the dryer to either the right or left side.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

This dryer is manufactured ready to install with a 3-wire

 

 

 

 

14" max.*

48 in.2 *

 

 

 

 

(35.6cm)

18"*

 

 

 

 

 

(310 cm2 )

 

 

 

 

 

 

(45.7 cm)

 

 

 

 

 

 

 

 

 

 

 

 

24 in.2 *

 

 

 

 

 

 

(155 cm2 )

1"

29"

1"

1"*

29¼"

5"

 

(2.5 cm)

(73.7 cm)

(2.5 cm)

(2.5 cm) (74.3 cm) (12.7 cm)

 

A

 

 

B

 

 

3"* (7.6 cm)

3"* (7.6 cm)

C

electrical supply connection. The neutral ground conductor is

permanently connected to the neutral conductor (white wire)

within the dryer. If the dryer is installed with a 4-wire electrical

supply connection, the neutral ground conductor must be

removed from the external ground connector (green screw),

and secured under the neutral terminal (center or white wire)

of the terminal block. When the neutral ground conductor is

secured under the neutral terminal (center or white wire) of

the terminal block, the dryer cabinet is isolated from the

neutral conductor.

If local codes do not permit the connection of a neutral

ground wire to the neutral wire, see “Optional 3-wire

connection” in “Electrical Connection - U.S.A. Only” section.

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

*Required spacing

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA- Z240 MH.

Mobile home installations require:

Metal exhaust system hardware, which is available for purchase from your dealer.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

ElectricalRequirements -U.S.A.Only

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

The National Electric Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A 4-wire power supply connection must be used when the

appliance is installed in a location where grounding through

the neutral conductor is prohibited. Grounding through the

neutral is prohibited for (1) new branch-circuit installations,

(2) mobile homes, (3) recreational vehicles, and (4) areas

where local codes prohibit grounding through the neutral

conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

5

Page 5
Image 5
Whirlpool W10151493A manual ElectricalRequirements -U.S.A.Only, Electrical Connection, Mobile home installations require

W10151493A, W10151492A specifications

The Whirlpool W10151492A and W10151493A are innovative appliances designed to enhance convenience and efficiency in modern kitchens. Both models are part of Whirlpool's commitment to delivering top-quality home solutions that simplify everyday tasks.

One of the standout features of the W10151492A and W10151493A is the advanced technology that ensures optimal performance. These units are equipped with a powerful motor that provides superior cleaning results, making them ideal for tackling tough stains and grime. The appliances also utilize innovative washing methods that maximize water and energy efficiency, thus reducing the overall environmental impact and utility bills.

The W10151492A and W10151493A are designed with user-friendly controls, allowing homeowners to easily navigate through various settings and customize each wash cycle to their specific needs. The intuitive interface provides clear indicators and options, making it simple for anyone to operate the appliance without a steep learning curve.

Another notable characteristic of these models is their spacious capacity. With ample interior space, users can wash larger loads in a single cycle, making them perfect for families or those who frequently entertain guests. The stainless steel drum not only ensures longevity and resistance to stains but also enhances the overall aesthetic of the appliance, providing a sleek and modern look.

These models also incorporate smart technology features, allowing users to monitor and control their appliances remotely. Whether it’s starting a load from a smartphone or receiving notifications when the wash is complete, these conveniences align perfectly with today’s fast-paced lifestyle.

Moreover, the sound-dampening technology minimizes noise during operation, ensuring that the appliances function quietly in the background, allowing for an undisturbed home environment. This is especially important in open-concept living spaces, where noise from kitchen appliances can disrupt daily activities.

In summary, the Whirlpool W10151492A and W10151493A not only boast impressive technology and features that cater to modern-day convenience but also prioritize efficiency, capacity, and user-friendliness. With these models, consumers can expect quality performance that aligns with their busy lifestyles while contributing to a more sustainable home.