GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
LP Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect
Reconnect the
Failure to follow these instructions can result in death or serious burns to children and adults.
1.Turn the manual shutoff valve to the closed position.
2.Unplug range or disconnect power.
B
A
C
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
To Convert Gas Pressure Regulator
1.Remove storage drawer or warming drawer. See “Replace Oven Racks and Storage or Warming Drawer” section.
2.Locate gas pressure regulator at rear of storage or warming drawer compartment.
NOTE: On models with a warming drawer, an access cover must be removed from the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
3.Remove plastic cover from gas pressure regulator cap.
4.Turn gas pressure regulator cap counterclockwise with a ⁵⁄₈" combination wrench to remove.
NOTE: Do not remove the spring beneath the cap.
F
Side view before
A
|
|
| NG | |
B |
|
| NG | |
F | D | E | ||
| ||||
|
|
| LP | |
C | Side view after |
| LP | |
|
|
|
A. Plastic cover
B. Gas pressure regulator cap with solid end facing out C. Gas pressure regulator cap with hollow end facing out D. Washer
E. Gas pressure regulator cap
F. Gas regulator shutoff valve (shown in the “open” position
5.Turn over the gas pressure regulator cap and reinstall on regulator so that the hollow end faces out and the marking “<- LP” is facing the direction shown in the above drawing.
6.Replace plastic cover over gas pressure regulator cap.
12