Style 2: Direct wire strain relief | ■ Assemble a UL listed conduit connector in the opening. |
■ Use Phillips screwdriver to remove screws and slide |
|
cord/conduit plate down and out. |
|
■Position cord/conduit plate as shown in the following illustration.
■Replace cord/conduit plate and insert screws.
A
B
A. Removable retaining nut
B. Strain relief
■Feed the flexible conduit through the strain relief, allowing enough slack to easily attach wiring to the terminal block.
■Tighten strain relief screw against the flexible conduit.
5.Replace back panel and screws on rear of range.
6.Complete installation following instructions for your type of electrical connection: