Whirlpool W10270322A installation instructions Style 2 Direct wire strain relief

Models: W10270322A

1 16
Download 16 pages 15.6 Kb
Page 9
Image 9
Style 2: Direct wire strain relief

Style 2: Direct wire strain relief

Assemble a UL listed conduit connector in the opening.

Use Phillips screwdriver to remove screws and slide

 

cord/conduit plate down and out.

 

Position cord/conduit plate as shown in the following illustration.

Replace cord/conduit plate and insert screws.

Manual backgroundA

B

A. Removable retaining nut

B. Strain relief

Feed the flexible conduit through the strain relief, allowing enough slack to easily attach wiring to the terminal block.

Tighten strain relief screw against the flexible conduit.

5.Replace back panel and screws on rear of range.

6.Complete installation following instructions for your type of electrical connection:

4-wire(recommended)

3-wire(if 4-wire is not available)

9