Electrical Connection Options

If your home has:

And you will be

Go to Section:

 

connecting to:

 

4-wire receptacle

A UL listed,

4-wire connection:

(NEMA type 14-50R)

250-volt

Power supply cord

 

minimum,

 

 

40-amp, range

 

 

power supply

 

 

cord

 

4-wire direct

A fused

4-wire connection:

 

disconnect or

Direct wire

 

circuit breaker

 

5"

box

 

(12.7 cm)

 

 

3-wire receptacle

A UL listed,

3-wire connection:

(NEMA type 10-50R)

250-volt

Power supply cord

 

minimum,

 

 

40-amp, range

 

 

power supply

 

 

cord

 

3-wire direct

A fused

3-wire connection:

1"

disconnect or

Direct wire

(2.5 cm)

circuit breaker

 

 

box

 

3"

 

 

(7.6 cm)

 

 

4-wire connection: Power Supply Cord

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes

Recreational vehicles

In an area where local codes prohibit grounding through the neutral

1.Part of metal ground strap must be cut out and removed.

A

B

C

A. Metal ground strap

B.Discard

C.Ground-link screw

2.Use Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground link screw and the end of the ground-link under the screw.

3.Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A

B

C

D

A. Terminal block

B.Ground-link screw

C.Cord/conduit plate

D.Power supply cord wires

4.Use Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw. The ground wire must be attached first.

5.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

A

F

 

B

 

C

E

 

 

D

A. 10–32 hex nut

D. Green ground wire

B. Ground-link screw

E. Neutral (center) wire

C. Line 1 (black)

F. Line 2 (red)

6.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.

7.Securely tighten hex nuts.

NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

8.Replace terminal block access cover.

10

Page 10
Image 10
Whirlpool W10270322A installation instructions Wire connection Power Supply Cord