Whirlpool W10270322A Electrical Connection - U.S.A. Only, Power Supply Cord, Direct Wire

Models: W10270322A

1 16
Download 16 pages 15.6 Kb
Page 8
Image 8
Electrical Connection - U.S.A. Only

Electrical Connection - U.S.A. Only

Power Supply Cord

Power Supply CordWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, fire, or electrical shock.

Direct Wire

Direct WireWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

1.

Disconnect power.

Style 1: Power supply cord strain relief

2.

Use Phillips screwdriver to remove the terminal block cover

Assemble a UL listed strain relief in the opening.

 

screw located on the back of the range. Pull cover down and

 

 

toward you to remove cover.

 

A

A. UL listed strain relief

3.Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.

Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

Tighten strain relief screw against the power supply cord.

4.Add strain relief.

8

Page 8
Image 8
Whirlpool W10270322A installation instructions Electrical Connection - U.S.A. Only, Power Supply Cord, Direct Wire