Installation Clearances
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
A
D
C B
NOTES:
After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may need to be shortened to avoid interfering with the regulator.
Electrical Requirements
WARNING
J
K E
FG
H
Electrical Shock Hazard
LN
MI
A. 30" (76.2 cm) on 30" (76.2 cm) models; 36" (91.4 cm) on 36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet (24" [61.0 cm] minimum clearance if bottom of wood or metal cabinet is covered by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper). If installing a range hood see NOTES.*
D. 13" (33.0 cm) recommended upper cabinet depth E. 1¹⁄₈" (2.8 cm)
F. 20" (50.8 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop
H. Grounded outlet - Locate within 24" (61.0 cm) of right rear corner of cutout
I. 29" (73.7 cm) on 30" (76.2 cm) models; 35¼" (89.5 cm) on 36" (91.4 cm) models
J. 24" (61.0 cm) minimum countertop depth is required
K. 2⁷⁄₈" (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below underside of countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended
M. 8" (20.3 cm) minimum distance to nearest left side combustible surface.**
N. 8" (20.3 cm) minimum distance to nearest right side combustible surface.**
30" (76.2 cm) Cooktop Overall: M + N must equal 48" (122.0 cm) minimum + 29" (73.7 cm) cutout for cooktop or 77" (195.6 cm)
36" (91.4 cm) Cooktop Overall: M + N must equal 48" (122.0 cm) minimum + 35¼" (89.5 cm) cutout for cooktop or 83¼" (211.5 cm)
**M + N combined must be at least 48" (122.0 cm) minimum overall Example 1: M = 8" (20.3 cm) left side + N = 40" (101.6 cm) right side = 48" (122.0 cm)
Example 2: M = 24" (61.0 cm) left side + N = 24" (61.0 cm) right side = 48" (122.0 cm)
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
IMPORTANT: The cooktop must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio
■A 120 volt, 60 Hz, AC only,
■Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides
■The Tech Sheet provided is located inside the cooktop on the left wall of the cooktop base.