4.Remove the cap from the gas pressure regulator using a flat- blade screwdriver.

A

A.Cap

5.Turn the cap over so that “N” or “NAT” is visible.

A

A. Cap

6.Reinstall the cap.

To Convert Surface Burners

1.Remove burner grate, burner caps and burners.

A

B

A. Burner cap

B.Burner

2.Locate the Natural gas orifice spuds for top burners in the package containing literature included with the range. Three Natural gas spuds are stamped “149” and one “165.”

3.Remove the LP gas orifice spuds using a 7 mm combination wrench.

4.Install the Natural gas orifice spuds using a 7 mm combination wrench.

A

B

A.Spud

B.Holder

NOTE: Depending on model, the range cooktop may be equipped with 4 standard burners or 3 standard burners and 1 super burner. Spud size and location remain the same.

For models with 4 standard burners:

Std Burner 149

Std Burner 149

Std Burner 149

Std Burner 149

For models with 3 standard burners and 1 super burner:

Std Burner 149

Std Burner 149

Super Burner 165

Std Burner 149

5.Place LP gas orifice spuds in the parts bag for future use and keep with the package containing literature.

6.Reinstall burners, burner caps and burner grates.

17

Page 17
Image 17