Sizing the Unit to the Room

Sizing the Unit to the Room

Model

Cellar Volume

AMP’s

AMP’s

Product Dimensions

 

 

 

 

 

 

(cubic feet)

(starting)

(running)

(W x H x D)

 

 

 

 

 

4000

1000

32

9

14.25” x 15.75” x 25.5”

 

 

 

 

 

8000

2000

36

10

14.25” x 22” x 27”

8000ti

2000 high

36

10

14.25” x 22” x 27”

8000ti

1750 med

36

10

14.25” x 22” x 27”

 

 

 

 

 

8000ti

1500 low

36

10

14.25” x 22” x 27”

Cutting the Hole for the WhisperKOOL Unit

Tools Needed

Level

Hammer

Screwdriver

Saw

Locate the center of the wall upon which the unit will be installed. Using a stud finder, locate the studs on either side of the center point, and mark them with vertical lines.

Mark the horizontal lines with a level

Using a saw, cut along the uppermost horizontal line until your saw reaches the stud. Turn the saw around, inserting it into the cut you have just made, and cut toward the opposite stud so that you have a clean hori- zontal cut between the two studs. Be careful not to cut into the studs themselves.

Now make the second horizontal cut from stud to stud on the line 16” below the first cut.

Using a level and a pencil, mark a horizontal line on the wall between the two studs, approximately 1.25” (or as close as possible if more than 1.25”) from the ceiling.

Using a ruler or measuring tape, measure 16” down, and mark another horizontal line parallel to the first one.