WhisperKool 8000, PT-EXPL, EXTREME SERIES, 4000 Installation Options, Exterior Grille Installation

Models: 4000 8000ti 8000 EXTREME SERIES PT-EXPL

1 38
Download 38 pages 22.3 Kb
Page 17
Image 17
INSTALLATION OPTIONS

INSTALLATION OPTIONS

Exterior Grille Installation

The exterior grille is required on all installations where the condenser side of the unit is exposed to the outside of the dwelling (i.e. rain and weather).

The condenser grille must be removed. Locate the screws at the bottom of the grille and remove. Using me- dium force, push the grille upward and lift the grille away from the unit. Replace the bottom screws and tighten the upper screws.

Now determine at what depth the unit will be installed:

For a non-flush installation (i.e. holes location #1 WhisperKOOL retrofit or #2 Middle Wall), place the grille on the condenser end and line up the holes on the grille with the holes on unit location #3. Use the 10 screws provided to fasten the grille to the unit.

For a flush installation, place the grille on the condenser side and then place the mounting bracket over the grille sides, “stacking” them. Align the holes and fasten with the 10 screws provided.

Non-Flush Installation

Flush Installation