SPECIFICATIONS
Switch Action: SPDT (Heating - open on rise) (Cooling - close on rise)
Temperature Range: 36°F to 90°F (2°C to 32°C)
!CAUTION
When the thermostat is set below 40°F (5°C), damage to the building and/or contents may result due to freezing. This is possible due to factory calibration tolerances, thermostat loca- tion and operating characteristics of the heating equipment.
System Switch: Heat - Off - Cool
Fan Switch : Low - Medium - High
Contact Structure: | Snap action |
|
| |||
Electrical Rating: |
|
|
|
|
| |
|
|
|
|
|
|
|
| VOLTAGE (AC) |
| 120V |
| 240V | 277V |
| Full Load Amps. |
| 5.5 |
| 2.75 | 2.3 |
|
|
|
|
|
|
|
| Locked Rotor Amps. |
| 33.0 |
| 16.5 | 13.8 |
| Pilot Duty |
|
|
| 125VA |
|
Mounting: Standard 2 x 4 inch outlet box or
INSTALLATION
SELECT THERMOSTAT LOCATION
Proper location insures that the thermostat will provide a comfortable home temperature. Observe the following general rules when selecting a location:
1.Locate thermostat about 5 ft. above the floor.
2.Install thermostat on a partitioning wall, not on an outside wall.
3.Never expose thermostat to direct light from lamps, sun, fireplaces or any temperature radiating equip- ment.
4.Avoid locations close to windows, adjoining outside walls, or doors that lead outside.
5.Avoid locations close to air registers or in the direct path of air from them.
6.Make sure there are no pipes or duct work in that part of the wall chosen for the thermostat location.
7.Never locate thermostat in a room that is warmer or cooler than the rest of the home, such as the kitchen.
8.Avoid locations with poor air circulation, such as behind doors or in alcoves.
9.The living or dining room is normally a good location, provided there is no cooking range or refrigerator on opposite side of wall.
INSTALL THERMOSTAT
Install the thermostat as follows:
1.Before mounting, connect system wiring to proper
2.Remove thermostat cover by grasping top and bottom of cover and pull straight out. Dress wiring into junction box and secure thermostat to outlet box with mounting screws.
NOTE
DO NOT PUSH OR DAMAGE THE KNOB SENSING ELEMENT DURING INSTALLATION.
3.Install thermostat cover, turn knob to desired setting, and set selector switches for the appropriate system function and fan speed.
ADAPTER PLATE (NOT PROVIDED)
4 x 4
JUNCTION BOX
!CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
The thermostat may be mounted on a standard 2 x 4 inch vertical outlet box or
COPPER CONDUCTORS ONLY.
FAN
LOW
HEAT
SYSTEM
USE 2 x 4 OR 4 x 4
JUNCTION BOX
MOUNTING
SCREWS (2)
|
| 70 | 80 | 90 |
50 | 60 |
|
| |
|
|
|
| |
| ||||
WHITE |
|
|
| |
60 |
|
| 70 | |
|
|
|
|
80
50
90
40
2