1 & 2)Keypad Lockout – This menu selection will display “Lk” and “OFF” (default, keypad not locked out). The and are used to toggle the selection between OFF and “L” (keypad locked out). When the keypad lockout selection is enabled “L”, and the MENU button is pressed again, the display will indicate the number “0” (default, still disabled) in the time digits. The

and are used to set the combination number from 0 to 999. If a combination of 0 is selected and the MENU button is pressed, the menu will be exited and keypad will not be locked. If 1 to 999 is selected and the MENU button is pressed, the combination is stored into memory and the menu is exited. The “LOC” will display designat- ing keypad locked with a valid combination. The SYSTEM button will operate for 10 seconds after the menu mode is exited to allow the user to change the mode from “OFF” to the desired SYSTEM mode.

While the keypad is locked out, a press of MENU will en- ter the configuration menu. The first menu item displayed

is the combination code “0”. The or keys are used to set the combination unlock number from 0 to

999. If the unlock number matches exactly with the com- bination lock number stored in memory when the MENU button is pressed, the keypad is unlocked and the “LOC” is removed. If the unlock number does not match when the MENU button is pressed, the combination returns to “0” for another attempt to set the unlock code. To exit the menu without unlocking the keypad, press RUN SCHED.

To reset the combination code and unlock the keypad if the code is forgotten, see troubleshooting section.

3)This control can be configured for:

MS 2 – Multi-Stage System (no heat pump)

HP 1 – Heat Pump with one stage of compressor SS 1 – Single Stage System

4)GAS or Electric (ELE) fan operation. If the heating sys- tem requires the thermostat to energize the fan, select ELE. Select GAS if the heating system energizes the fan on a call for heat.

5)Select Cool Savings™ value – Selects the amount of adjustment for the Cool Savings™ feature in Cool mode with 1 (1°) being the least amount of adjustment and 6 (6°) being the most amount of adjustment. Default value is 0 which disables this feature. Cool Savings is an optional energy saving feature that can reduce your cooling costs. It is based on the principal that lower indoor humidity makes a slightly higher temperature feel more comfortable. Cool Savings operates during periods of high demand which normally occur on the hottest summer days when a cooling system may run for hours to reach the thermostat setting. Long cooling run times also lower the indoor humidity. Cool Savings, very slowly, adjusts the setpoint temperature to make the setpoint closer to the displayed room temperature, to a maximum of the number of degrees you select. Adjust- ing the setpoint temperature over a long cooling run time allows the system to reach your set temperature and turn off. The room temperature will actually be higher than the thermostat displays but the reduction in humidity will allow comfort at the slightly higher temperature.

To turn this feature on in the Cool mode press Cool Savings. The display will show “Save” next to the setpoint temperature. When Cool Savings is making ad- justments to the room temperature display “Save” will be flashing and the displayed room temperature may vary within the adjustment range you selected.

If “Save” is not displayed and this feature is OFF, no change will occur when the cooling system is continu- ously running during periods of high demand.

6)Energy Management Recovery: (this step is skipped if configured to be non-programmable). Energy Manage-

INSTALLER/CONFIGURATION MENU

ment Recovery (E) On enables the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heat- ing will start 5 minutes early for every 1° of temperature required to reach setpoint.

Example: E On is selected and your heating is pro- grammed to 65° at night and 70° at 7 AM. If the build- ing temperature is 65°, the difference between 65° and 70° is 5°. Allowing 5 minutes per degree, the thermostat setpoint will change to 70° at 6:35 AM. Cooling allows more time per degree, because it takes longer to reach set temperature.

7, 8, 9 & 10) Cycle Rate Selection – The factory default set- ting for Heat and Cool modes, SS1 and MS2 is medium cycle (ME). For Heat Pump and HP1, the default setting is medium (ME). For Emer (Aux) the default setting is fast

cycle (FA). To change cycle rate, press the or key.

Cycle rate differentials for different settings are:

 

Fast

Medium Slow

MODE

FA

ME

SL

Heat (SS1, MS2)

0.4°F

0.6°F

1.7°F

Cool (SS1, MS2)

0.9°F

1.2°F

1.7°F

Heat Pump (HP1)

0.9°F

1.2°F

1.7°F

Emer (HP1)

0.6°F

-

1.7°F

11)Select Compressor Lockout CL OFF or ON – Select- ing CL ON will cause the thermostat to wait 5 minutes between cooling cycles. This is intended to help protect the compressor from short cycling. Some newer com- pressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay oc- curs, it will flash the setpoint for up to five minutes.

12)System Mode Configuration – This thermostat is con- figured for Heat and Cool with Auto Changeover (SYS- TEM switch with Heat, Auto, Cool, Off). It can also be configured for Heat and Cool (Heat, Cool, Off), Heat only

with Fan (Heat, Off, FAN Switch) Heat only without Fan (Heat, Off) Auto only (Auto, Off) and Cool only (Cool, Off).

13)Select Backlight Display – The display backlight im- proves display contrast in low lighting conditions. When the “C” terminal is powered, selecting backlight CdL ON will keep the light on continuously. Select backlight OFF will turn the light on momentarily after any key is pressed. When the “C” terminal is not powered, the light will be on momentarily after any key is pressed no matter whether the backlight is selected ON or OFF.

14)Select Temperature Display Adjustment 4 LO to 4 HI

– Allows you to adjust the room temperature display up to 4° higher or lower. Your thermostat was accurately cali- brated at the factory, but you have the option to change the display temperature to match your previous thermo- stat. The current or adjusted room temperature will be displayed.

15)Select F° or C° Readout – Changes the display readout to Celsius or Fahrenheit as required.

16)Limited Heat Range – This feature provides a maximum setpoint temperature for heat. The default setting is 90°F. It can be changed between 62°F and 89°F by pressing

the or key.

17)Limited Cool Range – This feature provide a minimum setpoint temperature for cool. The default setting is 45°F. It can be changed between 46°F and 82°F by pressing

the or key.

18)Program Options: 1F85 only, configured for 5+1+1 day or 5+2 day programming or non-programming mode. The default setting is P3, indicating 5+1+1 day programming.

5

Page 5
Image 5
White Rodgers 1F83-0422 Thermostat, 1F85-0422 specifications Select Temperature Display Adjustment 4 LO to 4 HI, Or key

1F83-0422 Thermostat, 1F85-0422 specifications

The White Rodgers 1F85-0422 is a highly regarded thermostat known for its innovative features and user-friendly design, making it a popular choice among homeowners and HVAC professionals alike. This programmable thermostat is designed to enhance energy efficiency and comfort in residential settings, allowing users to maintain optimal temperature settings with ease.

One of the standout features of the 1F85-0422 is its programmable functionality, which allows users to set specific heating and cooling schedules for different times of the day and week. This capability helps in reducing energy consumption, as the thermostat can adjust the temperature when the home is unoccupied or during the night when lower temperatures are preferred. With four programmable periods per day, users can easily customize their comfort levels according to their daily routines.

The 1F85-0422 also incorporates advanced technology, including a large, easy-to-read display that clearly shows the current temperature and settings. The backlit LCD screen ensures visibility even in dim lighting, providing convenience for nighttime adjustments. This thermostat features intuitive controls that allow users to navigate through the settings quickly, promoting a straightforward user experience.

Another key characteristic of the White Rodgers 1F85-0422 is its compatibility with various heating and cooling systems. It is designed to work efficiently with gas, electric, and heat pump systems, making it a versatile choice for a wide range of home HVAC configurations. The thermostat also supports multi-stage heating and cooling, ensuring precise temperature control and comfort throughout the home.

Energy-saving features are at the forefront of the 1F85-0422’s design. The thermostat is equipped with an energy-saving mode that optimizes heating and cooling cycles based on the user's preferences and occupancy patterns. Additionally, it provides alerts for regular maintenance, such as filter changes, to ensure that the HVAC system operates at peak efficiency.

In summary, the White Rodgers 1F85-0422 is a programmable thermostat that excels in performance, versatility, and user convenience. Its advanced features, including easy programming, compatibility with various HVAC systems, and energy-saving technologies, make it a reliable choice for enhancing home comfort while minimizing energy costs. Whether you are looking to upgrade your current thermostat or improve your home's energy efficiency, the 1F85-0422 is an excellent option to consider.