White Rodgers 1F85ST-0422 specifications Troubleshooting, Symptom Possible Cause Correction Action

Models: 1F85ST-0422

1 8
Download 8 pages 14.66 Kb
Page 8
Image 8

TROUBLESHOOTING

Reset Operation

Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not

function correctly contact your heating/cooling service person or place of purchase.

Note: Be sure to review the installer configuration menu settings.

To reset the programming, clock and configuration settings,

press and and the VENT button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.

Symptom

Possible Cause

Correction Action

 

 

 

 

No Heat/No Cool/No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

 

panel loose or not properly installed.

interlock or door switch.

 

4.

Loose connection to thermostat or

Tighten connections.

 

 

system.

 

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2.

Furnace Lock-Out Condition. Heat

Many furnaces have safety devices that shut down when

 

 

may also be intermittent.

a lock-out condition occurs. If the heat works intermittently

 

 

 

contact the furnace manufacturer or local HVAC service

 

 

 

person for assistance.

 

3.

Heating system requires service or

Diagnostic: Set SISTEMA Switch to CALOR and raise the

 

 

thermostat requires replacement.

setpoint above room temperature. Within a few seconds

 

 

 

the thermostat should make a soft click sound. This sound

 

 

 

usually indicates the thermostat is operating properly. If

 

 

 

the thermostat does not click, try the reset operation listed

 

 

 

above. If the thermostat does not click after being reset

 

 

 

contact your heating and cooling service person or place

 

 

 

of purchase for a replacement. If the thermostat clicks,

 

 

 

contact the furnace manufacturer or a HVAC service

 

 

 

person to verify the heating is operating correctly.

 

 

 

 

No Cool

1.

Cooling system requires service or

Same as diagnostic for No Heat condition except set the

 

 

thermostat requires replacement.

thermostat to FRIO and lower the setpoint below the room

 

 

 

temperature. There may be up to a five minute delay before

 

 

 

the thermostat clicks in Cooling.

 

 

 

 

 

1.

Possible short in wiring.

Check each wire connection to verify they are not shorted

Heat, Cool or Fan

2.

Possible short in thermostat.

or touching together. No bare wire should stick out from

Runs Constantly

3.

Possible short in heat/cool/vent system.

under terminal block. Try resetting the thermostat as

 

4.

VENT Switch set to Fan ON.

described above. If the condition persists the manufacturer

 

 

 

of your system or service person can instruct you on how

 

 

 

to test the Heat/Cool system for correct operation. If the

 

 

 

system operates correctly, replace the thermostat.

 

 

 

 

Thermostat Setting &

1.

Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees. See

Thermostat Thermometer

 

requires adjustment.

Temperature Display Adjustment in the Configuration Menu

Disagree

 

 

section.

 

 

 

 

Furnace (Air Conditioner)

1.

The location of the thermostat and/or

Digital thermostats provide precise control and cycle faster

Cycles Too Fast or Too

 

the size of the Heating System may

than older mechanical models. The system turns on and

Slow (narrow or wide

 

be influencing the cycle rate.

off more frequently but runs for a shorter time so there is

temperature swing)

 

 

no increase in energy use. If you would like an increased

 

 

 

cycle time, choose bA for slow cycle in the Configuration

 

 

 

menu, step 6 (Calor), 7 (Frio) or 8 (Bomba de Calor). If an

 

 

 

acceptable cycle rate is not achieved, contact a local HVAC

 

 

 

service person for additional suggestions.

 

 

 

 

 

HOMEOWNER HELP LINE: 1-800-284-2925

White-Rodgers is a division

 

 

 

 

 

 

of Emerson Electric Co.

 

 

 

The Emerson logo is a

 

 

 

trademark and service mark

 

 

 

8of Emerson Electric Co.

www.white-rodgers.com

Page 8
Image 8
White Rodgers 1F85ST-0422 specifications Troubleshooting, Symptom Possible Cause Correction Action, Reset Operation