Blue 4” Universal Thermostat with

Blue 4” Universal Thermostat with

Automatic Heat/Cool Changeover Option

Single Stage, Multi-Stage or Heat Pump

Installation and Operating Instructions for Model:

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Model

 

Programming Choices

 

 

 

 

1F85-0477

7 Day

 

5/1/1 Day

 

 

 

 

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

 

1F85-0477 Thermostat

 

 

 

Description

 

 

Heat Pump (No Aux. or Emergency Heat)

Yes

 

Heat Pump (with Aux. or Emergency Heat)

Yes

 

Systems with up to 2 Stages Heat, 2 Stages Cool

Yes

 

Heat Only Systems (with optional fan switch)

Yes

 

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

 

Cool Only Systems

Yes

 

Gas or Oil Heat

Yes

 

Electric Furnace

Yes

 

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

 

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

 

SPECIFICATIONS

Electrical Rating:

 

 

 

 

Battery Power

mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire

20 to 30 VAC

 

Terminal Load

1.5

A per terminal, 2.5A maximum all terminals combined

Setpoint Range

45° to 90°F (7° to 32°C)

Rated Differentials:

Fast

Med.

Slow

Heat (SS1, MS2)

0.4

°F

0.6 °F

1.7 °F

Cool (SS1, MS2)

0.9

°F

1.2 °F

1.7 °F

Heat Pump (HP1, HP2)

0.9

°F

1.2 °F

1.7 °F

Emer (HP1, HP2)

0.6

°F

1.7 °F

Operating Ambient

32° to +105°F (0° to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temperature Range

-40° to +150°F (-40° to +65°C)

Dimensions Thermostat

3-7/8”H x 5-1/8”W x 1-1/4”D

 

 

 

 

 

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Index

Page

Installation

2

Wiring Connections

2

Wiring Diagrams

3

Thermostat Quick Reference

5

Installer Configuration Menu

6

Operating Your Thermostat

8

Programming

9

Troubleshooting

10

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this product may replace a product that contains mercury.

Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury.Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container. Refer to www.white-rodgers.comfor location to send product containing mercury.

 

PART NO. 37-7238A

www.white-rodgers.com

 

www.emersonclimate.com