White Rodgers 1F95-391 specifications Service Reminder, Service Button Menu, Time Fwd, Prgm

Models: 1F95-391

1 12
Download 12 pages 39.93 Kb
Page 8
Image 8
SERVICE REMINDER

SERVICE REMINDER

The Service Button Menu allows you to view or program as many as 4 reminders that indicate when service is required.

1.Humidifiers = A programmable run time in hours to indicate on the LCD when the humidifier will need to be serviced.

2.Air Filters = A programmable run time in hours to indicate on the LCD when the filter will need to be serviced or replaced.

3.UV Lights = A programmable run time in days to indicate on the LCD when the Ultra-Violet Bulb will need to be replaced.

4.Service Timer = A programmable run time in days to indicate on the LCD when to call your service contractor.

To enter the Service Button Menu when no service reminders are on the display, press and

release the

 

 

TIME

FWD

to step through the menu items. To turn a menu item

 

 

OFF

or ON

when selected, press

setting an item to

ON

, you can then use

or

to

select the time interval. Press

RUN

normal operation.

 

 

 

 

 

 

 

SERVICE

button. Press

or

. If you are

to exit the menu and return to

 

When

a service reminder appears on

the display, press the

SERVICE

button to remove it and reset the timer to begin the count

down

to the next service interval.

 

 

 

Service Button Menu

Step

Press Button(s)

1SERVICE

2TIME FWD

(If PAD TIME is ON)

3

TIME

FWD

4TIME FWD

(If FLTR TIME is ON)

5

TIME FWD

6TIME FWD

(If UV TIME is ON)

7TIME FWD

8TIME FWD

(If SERV TIME is ON)

PRGM

RUN

Displayed

Press

or

to select:

(Factory Default)

 

 

 

PAD TIME

 

 

(ON)

(OFF) Hrs

 

 

or

or

 

 

(OFF)

REM PAD TIME

 

 

 

No. of Hrs

 

 

 

SET PAD TIME

 

 

25 to 1975

(100) Hrs

 

 

 

FLTR TIME

 

 

(ON)

(OFF) /Hrs

 

 

or

or

 

 

(OFF)

REM FLTR TIME

 

 

 

No. of Hrs

 

 

 

SET FLTR TIME

 

 

25 to 1975

(200) Hrs

 

 

 

UV TIME

 

 

(ON)

(OFF) Days

 

 

or

or

 

 

(OFF)

REM UV TIME

 

 

 

No. of Days

 

 

 

SET UV TIME

 

 

25 to 1975

(375) Days

 

 

 

SERV TIME

 

 

(ON)

(OFF) Days

 

 

or

or

 

 

(OFF)

REM SERV TIME

 

 

No. of Days

 

 

 

SET SERV TIME

 

25 to 1975

(175) Days

 

 

 

 

 

 

 

COMMENTS

Set Humidifier Maintenance Reminder.

Selects time intervals in increments of 25 hours. The RUN time accumulates when the HM terminal is energized.

Set Air Filter Maintenan

ce Reminder

.

Selects time intervals in increments of 25 hours.

The RUN time accumulates when the fan is operating.

Selects UV Light Maintenance Reminder.

Selects time intervals in increments of 25 days. The RUN time is the calendar time from when it is entered or reset.

Selects Routine Maintenance Service Call Reminder.

Selects time intervals in increments of 25 days. The RUN time is the calendar time from when it is entered or reset.

Return

s to Normal Operation.