White Rodgers 1F95-71 installation instructions

Models: 1F95-71

1 8
Download 8 pages 17.7 Kb
Page 5
Image 5
IF SAFETY CIRCUITS ARE IN ONLY ONE OF THE SYSTEMS, REMOVE THE TRANSFORMER OF THE SYSTEM WITH NO SAFETY CIRCUITS.

NOTE

IF SAFETY CIRCUITS ARE IN ONLY ONE OF THE SYSTEMS, REMOVE THE TRANSFORMER OF THE SYSTEM WITH NO SAFETY CIRCUITS.

 

 

O

Y1

Y2

G

CUT AND

 

CHANGEOVER

COMPRESSOR

 

 

ENERGIZED

CONTACTOR

 

TAPE OFF!

 

IN COOL

STAGE 2

 

 

 

 

HOT

 

 

 

 

 

120 VAC

24 VAC

 

COMPRESSOR

FAN

 

 

 

CONTACTOR

 

 

 

RELAY

NEUTRAL

 

 

STAGE 1

 

 

 

 

 

 

 

 

 

 

B

W1

W2

W3

 

HEAT

 

HEAT

 

RELAY

 

RELAY

 

STAGE 1

 

STAGE 3

CHANGEOVER

HEAT

 

ENERGIZED

 

RELAY

 

IN HEAT

 

STAGE 2

 

THERMOSTAT

CONTROL

CIRCUIT

THERMOSTAT

RC

SYSTEM

HOT

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

NEUTRAL

DEPENDING ON SYSTEM

REQUIREMENTS, REPLACE WITH A 75VA TRANSFORMER, IF NEEDED

TWO COMMONS MUST

BE JUMPERED TOGETHER!

Figure 5. Typical wiring diagram for two-transformer systems with NO safety circuits

NOTE

Relay contacts shown are thermostatically operated. The accessory relay scheme is required when safety circuits exist in both systems.

!CAUTION

Polarity must be observed. If the HOT side of the second transformer is jumpered to the COMMON side of the first transformer a short will be made. Damage to equipment will occur when power is restored.

THERMOSTAT

CONTROL

CIRCUIT

O

Y1

Y2

G

CHANGEOVER

COMPRESSOR

 

ENERGIZED

CONTACTOR

 

IN COOL

STAGE 2

 

 

COMPRESSOR

FAN

 

CONTACTOR

 

RELAY

 

STAGE 1

 

 

 

 

B

W1

W2

W3

C

R

 

HEAT

 

HEAT

 

 

 

RELAY

 

RELAY

 

 

 

STAGE 1

 

STAGE 3

 

 

CHANGEOVER

HEAT

 

 

 

ENERGIZED

 

RELAY

 

 

 

IN HEAT

 

STAGE 2

 

 

 

LIMIT OR

SAFETY

SWITCHES

24VAC

ACCESSORY RELAY N.O.

CONTACT

COMMON

 

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIMIT OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAFETY

 

HOT

24 VAC

 

 

 

 

 

120 VAC

SWITCHES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

 

TRANSFORMER

 

 

 

TWO COMMONS MUST

BE JUMPERED TOGETHER!

 

LIMIT OR

 

 

 

 

 

 

 

 

 

LIMIT OR

 

 

SAFETY

 

 

 

 

 

 

 

 

 

SAFETY

HOT

 

 

 

 

 

 

 

SWITCHES

 

 

 

 

 

 

 

 

 

SWITCHES

 

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

 

 

120 VAC

 

 

COMMON

 

 

 

 

 

 

 

 

 

NEUTRAL

COOLING

TRANSFORMER

Figure 6. Typical wiring diagram for two-transformer systems with safety circuits in BOTH systems

5

Page 5
Image 5
White Rodgers 1F95-71 installation instructions