INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays menu item #1 in the table below. Press to advance to the next menu item or to return to a previous menu item. Press or to change a menu item.
|
|
|
|
| CONFIGURATION MENU | ||||
Menu |
| Non- |
| Displayed | Press | or |
|
|
|
|
|
| |||||||
Reference | Program- | Program- | Press | (Factory | to select from |
| |||
Number | mable | mable | Button | Default) | listed options | Comments | |||
|
|
|
|
|
|
|
|
|
|
1 | 1 | 1 |
| (ELE) | GAS |
|
|
| GAS setting: furnace controls blower. |
|
|
|
|
|
|
|
|
| ELE setting: thermostat controls blower. |
2 | 2 | 2 |
| Days, (7) P | Programs per week. (0 = | ||||
3 | 3 | NA |
| PS (4) | 2 |
|
|
| Program periods per day. |
|
|
|
|
|
|
|
|
| 4 = Morning, Day, Evening, Night |
|
|
|
|
|
|
|
|
| 2 = Day, Night |
4 | 4 | 3 |
| System switch configuration. | |||||
|
|
|
|
| |||||
5 | 5 | NA |
| E (On) | OFF |
|
|
| Selects Energy Management Recovery, E (with programming option on) |
6 | 6 | 4 |
| Cr, Heat (FA) | SL |
|
|
| Selects Adjustable Anticipation, cycle rate, Heat |
|
|
|
|
|
|
|
|
|
|
7 | 7 | 5 |
| Cr, Cool (FA) | SL |
|
|
| Selects Adjustable Anticipation, cycle rate, Cool |
|
|
|
|
|
|
|
|
|
|
8 | 8 | 6 |
| CL (OFF) | On |
|
|
| Selects Compressor Lockout. |
9 | 9 | 7 |
| dL (On) | OFF |
|
|
| Selects Continuous Display backlight & intensity. |
|
|
|
|
|
|
|
|
|
|
10 | 10 | 8 |
| dL (LO) | HI |
|
|
| Selects Backlight Intensity. |
|
|
|
|
|
|
| |||
11 | 11 | 9 |
| 0 | 4, LO to 4, HI | Selects Adjustable Ambient Temperature Display [range | |||
|
|
|
|
|
|
|
|
| +4 (HI)]. |
12 | 12 | 10 |
| °F | °C |
|
|
| Selects °F/°C Display (temperature units in Fahrenheit or Celsius). |
13 | 13 | 11 |
| b (On) | OFF |
|
|
| Selects audible Beeper On/Off. |
14 | 14 | 12 |
| dS (On) | OFF |
|
|
| Selects Daylight Saving Time calculation. |
|
|
|
|
|
|
|
|
|
|
15 | 15 | 13 |
| AS, Heat (On) | OFF |
|
|
| Selects Automatic Schedule for comfort temperature Programming, |
|
|
|
|
|
|
|
|
| heat mode. |
16 | 16 | 14 |
| AS, Cool (On) | OFF |
|
|
| Selects Automatic Schedule for comfort temperature Programming, |
|
|
|
|
|
|
|
|
| cool mode. |
17 | 17 | 15 |
| CS, (OFF) |
|
| Selects Cool Saving Feature & amount. | ||
|
|
|
| Cool Savings |
|
|
|
|
|
18 | 18 | 16 |
| HL, Heat (99) |
|
|
| TEMPERATURE LIMIT, HEAT (max. heat set point). | |
|
|
|
|
|
|
|
|
|
|
19 | 19 | 17 |
| LL, Cool (45) |
|
|
| TEMPERATURE LIMIT, COOL (min. cool set point). | |
20 | 20 | 18 |
| OFF, | L (total), P (partial), | Selects Keypad Lockout. | |||
|
|
|
| Keypad Lockout | Temperature Limit |
| |||
|
|
|
|
| (limited temperature range) |
| |||
|
|
|
| 000 |
|
| Selects Keypad Lockout Combination (active only if keypad Lockout | ||
|
|
|
|
|
|
|
|
| is selected). |
21 | 21 | 19 |
| Remote (OFF) | On |
|
|
| Remote temperature sensor, enable/disable. |
|
|
|
| In, Remote | Outdoor Remote | Remote temperature sensor (Indoor/Outdoor). | |||
|
|
|
| LS (On) | OFF |
|
|
| Local temp. Sensor enable/disable (only when Indoor Remote is |
|
|
|
|
|
|
|
|
| selected On). |
|
|
|
|
|
|
|
|
|
|
22 | 22 | 20 |
| Change Filter | On |
|
|
| Selects Change filter feature |
|
|
|
| (OFF) |
|
|
|
|
|
|
|
|
| 200 Hours | Change filter, duration hours. | ||||
|
|
|
|
| of 25 hours) |
| |||
|
|
|
|
|
|
|
|
|
|
5