White Rodgers 1F97-1277 specifications Installer/Configuration Menu

Models: 1F97-1277

1 12
Download 12 pages 1.24 Kb
Page 5
Image 5
INSTALLER/CONFIGURATION MENU

INSTALLER/CONFIGURATION MENU

To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays menu item #1 in the table below. Press CONFIGURATION MENU to advance to the next menu item or Manual background to return to a previous menu item. Press Manual background or Manual background to change a menu item.

 

 

 

 

 

CONFIGURATION MENU

Menu

 

Non-

 

Displayed

Press

or

 

 

 

 

 

 

Reference

Program-

Program-

Press

(Factory

to select from

 

Number

mable

mable

Button

Default)

listed options

Comments

 

 

 

 

 

 

 

 

 

 

1

1

1

 

(ELE)

GAS

 

 

 

GAS setting: furnace controls blower.

 

 

 

 

 

 

 

 

 

ELE setting: thermostat controls blower.

2

2

2

 

Days, (7) P

5-1-1 or 0

Programs per week. (0 = non-programmable)

3

3

NA

 

PS (4)

2

 

 

 

Program periods per day.

 

 

 

 

 

 

 

 

 

4 = Morning, Day, Evening, Night

 

 

 

 

 

 

 

 

 

2 = Day, Night

4

4

3

 

Cool-Off-

Cool-Off-Heat,

System switch configuration.

 

 

 

 

Heat-Auto

Off-Heat, Cool-Off

 

5

5

NA

 

E (On)

OFF

 

 

 

Selects Energy Management Recovery, E (with programming option on)

6

6

4

 

Cr, Heat (FA)

SL

 

 

 

Selects Adjustable Anticipation, cycle rate, Heat

 

 

 

 

 

 

 

 

 

 

7

7

5

 

Cr, Cool (FA)

SL

 

 

 

Selects Adjustable Anticipation, cycle rate, Cool

 

 

 

 

 

 

 

 

 

 

8

8

6

 

CL (OFF)

On

 

 

 

Selects Compressor Lockout.

9

9

7

 

dL (On)

OFF

 

 

 

Selects Continuous Display backlight & intensity.

 

 

 

 

 

 

 

 

 

 

10

10

8

 

dL (LO)

HI

 

 

 

Selects Backlight Intensity.

 

 

 

 

 

 

 

11

11

9

 

0

4, LO to 4, HI

Selects Adjustable Ambient Temperature Display [range -4 (LO) to

 

 

 

 

 

 

 

 

 

+4 (HI)].

12

12

10

 

°F

°C

 

 

 

Selects °F/°C Display (temperature units in Fahrenheit or Celsius).

13

13

11

 

b (On)

OFF

 

 

 

Selects audible Beeper On/Off.

14

14

12

 

dS (On)

OFF

 

 

 

Selects Daylight Saving Time calculation.

 

 

 

 

 

 

 

 

 

 

15

15

13

 

AS, Heat (On)

OFF

 

 

 

Selects Automatic Schedule for comfort temperature Programming,

 

 

 

 

 

 

 

 

 

heat mode.

16

16

14

 

AS, Cool (On)

OFF

 

 

 

Selects Automatic Schedule for comfort temperature Programming,

 

 

 

 

 

 

 

 

 

cool mode.

17

17

15

 

CS, (OFF)

1-2-3-4-5-6

 

 

Selects Cool Saving Feature & amount.

 

 

 

 

Cool Savings

 

 

 

 

 

18

18

16

 

HL, Heat (99)

62-98

 

 

 

TEMPERATURE LIMIT, HEAT (max. heat set point).

 

 

 

 

 

 

 

 

 

 

19

19

17

 

LL, Cool (45)

46-82

 

 

 

TEMPERATURE LIMIT, COOL (min. cool set point).

20

20

18

 

OFF,

L (total), P (partial),

Selects Keypad Lockout.

 

 

 

 

Keypad Lockout

Temperature Limit

 

 

 

 

 

 

(limited temperature range)

 

 

 

 

 

000

001-999

 

 

Selects Keypad Lockout Combination (active only if keypad Lockout

 

 

 

 

 

 

 

 

 

is selected).

21

21

19

 

Remote (OFF)

On

 

 

 

Remote temperature sensor, enable/disable.

 

 

 

 

In, Remote

Outdoor Remote

Remote temperature sensor (Indoor/Outdoor).

 

 

 

 

LS (On)

OFF

 

 

 

Local temp. Sensor enable/disable (only when Indoor Remote is

 

 

 

 

 

 

 

 

 

selected On).

 

 

 

 

 

 

 

 

 

 

22

22

20

 

Change Filter

On

 

 

 

Selects Change filter feature

 

 

 

 

(OFF)

 

 

 

 

 

 

 

 

 

200 Hours

25-1975 (in increments

Change filter, duration hours.

 

 

 

 

 

of 25 hours)

 

 

 

 

 

 

 

 

 

 

 

5

Page 5
Image 5
White Rodgers 1F97-1277 specifications Installer/Configuration Menu