White Rodgers 1F97-1277 Enter the Heating Program, Enter the Cooling Program, Automatic Schedule

Models: 1F97-1277

1 12
Download 12 pages 1.24 Kb
Page 9
Image 9
Enter the Heating Program

PROGRAMMING

Fill in the blank schedule on the next page then:

Enter the Heating Program

1)Press the Menu button and then press Set Schedule. Press SYSTEM button to select either "Heat" or "Cool" in the system switch area indicating the active mode being programmed. You can switch to the other mode by pressing the system switch at any time.

2)The top of the display will show the day(s) being pro- grammed. The time and set at temperature are also displayed. "Morning" will also be displayed to indicate the period.

3)Press Enter the Cooling Program or Automatic Schedule key to change the temperature to your selected temperature for the 1st heating period (Morning).

4)Press Entering Fan Program or Manual background key to adjust the start time for period. The time will change in 15 minute increments.

5)Press FAN to select Auto or Prog.

6)After you have set the time and the temperature for the period to begin, press Set Schedule to advance to the next program period.

7)Repeat steps 2 through 6 until all of the program times and temperatures are set for all program periods on that day.

8)Press "Advance Day" to change to the next day and repeat steps 2 through 8.

9)When programming is complete and all of the times and temperatures match your desired heating schedule, press Run Schedule. The thermostat will now run your program.

Enter the Cooling Program

1)Press the SYSTEM button until the Cool icon appears.

2)Follow Enter Heating Program instructions for entering cooling times and temperatures.

Automatic Schedule

This feature provides a method to program every day with the most popular time and temperature profile using one key press. For this feature to be available, the Auto schedule options (AS Cool or AS Heat) should be set on in the installer configuration.

Select the desired “Comfort Temperature” in the setpoint. When the Auto Schedule touch key is pressed, it will start flashing indicating that it is now ready to insert the displayed temperature setpoint as the “Comfort Temperature” for the selected system mode currently in (Heat/Cool). A second press of the Auto Schedule touch key will complete the process. A 6 o F setback temperature will also be inserted for the night step. Once it is done, the touch key display Auto Schedule will disappear disabling any further operation of Auto Schedule touch key. If desired it can be enabled again in the installer configuration menu.

Entering Fan Program

This key is used to select FAN Auto operation (fan energized with a call for cool but not on with a call for heat) to FAN On (fan on continuous) or FAN PROG (fan programmed to cycle fixed time automatically). Each press of the FAN touch key will change the mode from Auto to On to Prog. FAN Auto or FAN On or FAN On Prog will display in the run mode for as long as the fan is in that position. When FAN Prog position is selected and the system key is in the Cool, Heat or Auto mode the circulator blower (fan) will cycle ON for 10 minutes, OFF for 20 minutes when the thermostat has not called for cooling or heating for the past 60 minutes.

To improve indoor air quality, the system circulator can be programmed to run during any program time period by touching the Fan touch key in the appropriate program time period when in the Menu mode for that particular day.

The display shall indicate Prog (under the Fan icon) when in Menu mode and the fan is programmed to come on during that time.

In the menu mode, each time the fan key is pressed, the fan operation and display will change from FAN Auto to FAN Prog. The display shall indicate FAN On Prog when in run mode and the fan is programmed to run for that particular time period.

When in Run Schedule mode and the FAN touch key is pressed, it will override the schedule, and the display and fan operation shall change to FAN Auto and the fan is stopped. Further key depression will change it to FAN On (continuous blower on) and to FAN Prog (cycling 10 minutes on and 20 minutes off if there is no call for heat or cool for 60 minutes). The Run Schedule touch key will also be indicated, meaning that it is an override on the scheduled program. The override will last until next schedule comes up or the Run Schedule touch key is depressed.

9

Page 9
Image 9
White Rodgers 1F97-1277 Enter the Heating Program, Enter the Cooling Program, Automatic Schedule, Entering Fan Program