FOR SIX ELEMENT FURNACES
COMBINATION Fan and Heater Loads
TWO-STAGE Room Thermostat Option After 3rd Element
|
|
| WIRING |
| M5 | M6 | To 5th element |
TWO POLE | M7 | M8 | To 6th element |
| H | H | To W2 of 24vAC wall thermostat |
| M1 | M2 | To fan interlock |
TWO POLE | M3 | M4 | To 4th element |
| H | H |
|
|
| (Two Timings) |
|
|
|
| |
| M5 | M6 | To common of 24v transformer |
TWO POLE | M7 | M8 | To 3rd element |
| H | H | To W1 of 24vAC wall thermostat |
| M1 | M2 | To fan & 1st element |
TWO POLE | M3 | M4 | To 2nd element |
| H | H |
|
|
| (Two Timings) |
|
|
|
|
SEPARATE Fan and Heater Loads
TWO-STAGE Room Thermostat Option After 2nd or 4th Element
|
|
| WIRING |
| M5 | M6 | To 6th element |
ONE POLE | H | H | To W2 of 24vAC wall thermostat |
| |||
| M1 | M2 | To fan interlock |
TWO POLE | M3 | M4 | To 5th element |
| H | H |
|
|
| (Two Timings) |
|
|
|
| |
| M5 | M6 | To common of 24v transformer |
TWO POLE | M7 | M8 | To 4th element |
| H | H | To W2 of 24vAC wall thermostat |
| M1 | M2 | To fan interlock |
TWO POLE | M3 | M4 | To 3rd element |
| H | H |
|
|
| (Two Timings) |
|
|
|
| |
| M5 | M6 | To common of 24v transformer |
TWO POLE | M7 | M8 | To 2nd element |
| H | H | To W1 of 24vAC wall thermostat |
| M1 | M2 | To fan |
TWO POLE | M3 | M4 | To 1st element |
| H | H |
|
(Two Timings)
DOTTED LINE BETWEEN "H" TERMINAL IS A
WIRING DIAGRAMS
FOR SEVEN ELEMENT FURNACES
COMBINATION Fan and Heater Loads
TWO-STAGE Room Thermostat Option After 3rd or 5th Element
|
|
| WIRING |
| M5 | M6 | To 7th element |
ONE POLE | H | H | To W2 of 24vAC wall thermostat |
| |||
| M1 | M2 | To fan interlock |
TWO POLE | M3 | M4 | To 6th element |
| H | H |
|
|
| (Two Timings) |
|
|
|
| |
| M5 | M6 | To common of 24v transformer |
TWO POLE | M7 | M8 | To 5th element |
| H | H | To W2 of 24vAC wall thermostat |
| M1 | M2 | To fan interlock |
TWO POLE | M3 | M4 | To 4th element |
| H | H |
|
|
| (Two Timings) |
|
|
|
| |
| M5 | M6 | To common of 24v transformer |
TWO POLE | M7 | M8 | To 3rd element |
| H | H | To W1 of 24vAC wall thermostat |
| M1 | M2 | To fan & 1st element |
TWO POLE | M3 | M4 | To 2nd element |
| H | H |
|
(Two Timings)
SEPARATE Fan and Heater Loads
|
|
| WIRING |
| M5 | M6 | To 6th element |
TWO POLE | M7 | M8 | To 7th element |
| H | H | To W2 of 24vAC wall thermostat |
| M1 | M2 | To fan interlock |
TWO POLE | M3 | M4 | To 5th element |
| H | H |
|
|
| (Two Timings) |
|
|
|
| |
| M5 | M6 | To common of 24v transformer |
TWO POLE | M7 | M8 | To 4th element |
| H | H | To W2 of 24vAC wall thermostat |
| M1 | M2 | To fan interlock |
TWO POLE | M3 | M4 | To 3rd element |
| H | H |
|
|
| (Two Timings) |
|
|
|
|
| M5 | M6 | To common of 24v transformer |
TWO POLE | M7 | M8 | To 2nd element |
| H | H | To W1 of 24vAC wall thermostat |
| M1 | M2 | To fan |
TWO POLE | M3 | M4 | To 1st element |
| H | H |
|
(Two Timings)
The Emerson logo is a trademark and service mark of Emerson Electric Co.