White Rodgers 24A34-3 For Six Element Furnaces, For Seven Element Furnaces, Wiring Diagrams

Models: 24A34-14 24A34-1 24A34-4 24A34-15 24A34-2 24A34-3 24A34-6 24A34-5

1 4
Download 4 pages 51.48 Kb
Page 4
Image 4
FOR SIX ELEMENT FURNACES

FOR SIX ELEMENT FURNACES

COMBINATION Fan and Heater Loads

TWO-STAGE Room Thermostat Option After 3rd Element

 

 

 

WIRING

 

M5

M6

To 5th element

TWO POLE

M7

M8

To 6th element

 

H

H

To W2 of 24vAC wall thermostat

 

M1

M2

To fan interlock

TWO POLE

M3

M4

To 4th element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-6

 

 

M5

M6

To common of 24v transformer

TWO POLE

M7

M8

To 3rd element

 

H

H

To W1 of 24vAC wall thermostat

 

M1

M2

To fan & 1st element

TWO POLE

M3

M4

To 2nd element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-6

 

SEPARATE Fan and Heater Loads

TWO-STAGE Room Thermostat Option After 2nd or 4th Element

 

 

 

WIRING

 

M5

M6

To 6th element

ONE POLE

H

H

To W2 of 24vAC wall thermostat

 

 

M1

M2

To fan interlock

TWO POLE

M3

M4

To 5th element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-6

 

 

M5

M6

To common of 24v transformer

TWO POLE

M7

M8

To 4th element

 

H

H

To W2 of 24vAC wall thermostat

 

M1

M2

To fan interlock

TWO POLE

M3

M4

To 3rd element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-6

 

 

M5

M6

To common of 24v transformer

TWO POLE

M7

M8

To 2nd element

 

H

H

To W1 of 24vAC wall thermostat

 

M1

M2

To fan

TWO POLE

M3

M4

To 1st element

 

H

H

 

(Two Timings)

24A34-6

DOTTED LINE BETWEEN "H" TERMINAL IS A FACTORY-INSTALLED JUMPER

WIRING DIAGRAMS

FOR SEVEN ELEMENT FURNACES

COMBINATION Fan and Heater Loads

TWO-STAGE Room Thermostat Option After 3rd or 5th Element

 

 

 

WIRING

 

M5

M6

To 7th element

ONE POLE

H

H

To W2 of 24vAC wall thermostat

 

 

M1

M2

To fan interlock

TWO POLE

M3

M4

To 6th element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-5

 

 

M5

M6

To common of 24v transformer

TWO POLE

M7

M8

To 5th element

 

H

H

To W2 of 24vAC wall thermostat

 

M1

M2

To fan interlock

TWO POLE

M3

M4

To 4th element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-6

 

 

M5

M6

To common of 24v transformer

TWO POLE

M7

M8

To 3rd element

 

H

H

To W1 of 24vAC wall thermostat

 

M1

M2

To fan & 1st element

TWO POLE

M3

M4

To 2nd element

 

H

H

 

(Two Timings)

24A34-6

SEPARATE Fan and Heater Loads

TWO-STAGE Room Thermostat Option After 3rd or 5th Element

 

 

 

WIRING

 

M5

M6

To 6th element

TWO POLE

M7

M8

To 7th element

 

H

H

To W2 of 24vAC wall thermostat

 

M1

M2

To fan interlock

TWO POLE

M3

M4

To 5th element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-6

 

 

M5

M6

To common of 24v transformer

TWO POLE

M7

M8

To 4th element

 

H

H

To W2 of 24vAC wall thermostat

 

M1

M2

To fan interlock

TWO POLE

M3

M4

To 3rd element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-6

 

 

M5

M6

To common of 24v transformer

TWO POLE

M7

M8

To 2nd element

 

H

H

To W1 of 24vAC wall thermostat

 

M1

M2

To fan

TWO POLE

M3

M4

To 1st element

 

H

H

 

(Two Timings)

24A34-6

White-Rodgers is a division of Emerson Electric Co.

The Emerson logo is a trademark and service mark of Emerson Electric Co.

www.white-rodgers.com www.emersonclimate.com

Page 4
Image 4
White Rodgers 24A34-3 For Six Element Furnaces, For Seven Element Furnaces, Wiring Diagrams, SEPARATE Fan and Heater Loads