White Rodgers 24A34-14, 24A34-2, 24A34-5 Wiring Diagrams, Fan Delay Off, For One Element Furnaces

Models: 24A34-14 24A34-1 24A34-4 24A34-15 24A34-2 24A34-3 24A34-6 24A34-5

1 4
Download 4 pages 51.48 Kb
Page 2
Image 2
FAN DELAY OFF

FAN DELAY OFF

 

 

WIRING

I

2

Normally close

 

3

Normally open

H

H

 

(One Timing)

24A34-15

FOR ONE ELEMENT FURNACES

COMBINATION Fan and Heater Loads

 

 

 

 

 

 

 

WIRING

ONE POLE

M1

 

 

 

M2

 

To 1st element & fan

 

 

 

H

 

 

 

H

 

To 24 VAC wall thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(One Timing) 24A34-1 / -2

SEPARATE Fan and Heater Loads

 

 

WIRING

M1

M2

To fan

TWO POLE M3

M4

To 1st element

H

H

To 24vAC wall thermostat

(One Timing) 24A34-3 / -4

FOR TWO ELEMENT FURNACES

COMBINATION Fan and Heater Loads

 

 

WIRING

M1

M2

To 1st element & fan

TWO POLE M3

M4

To 2nd element

H

H

To 24vAC wall thermostat

(One Timing) 24A34-3 / -4

SEPARATE Fan and Heater Loads

 

 

 

WIRING

 

M5

M6 To 2nd element or aux. contacts

ONE POLE

H

H

 

 

 

 

M1

M2

To fan

TWO POLE

M3

M4

To 1st element

 

H

H To 24vAC wall thermostat

 

 

(Two Timings)

 

 

 

24A34-5

 

DOTTED LINE BETWEEN "H" TERMINAL IS A FACTORY-INSTALLED JUMPER

WIRING DIAGRAMS

FOR THREE ELEMENT FURNACES WITH COMBINATION FAN & HEATER LOADS

SINGLE-STAGE Room Thermostat

 

 

 

WIRING

 

M5

M6

To 3rd element

ONE POLE

H

H

To 24vAC wall thermostat

 

 

M1

M2

To fan & 1st element

TWO POLE M3

M4

To 2nd element

 

H

H

 

(Two Timings)

24A34-5

TWO-STAGE Room Thermostat Option

 

 

 

WIRING

 

M5

M6

 

TWO POLE

M7

M8

To 3rd element

 

H

H To 24vAC wall thermostat

 

M1

M2 To fan & 1st element

TWO POLE

M3

M4

To 2nd element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-6

 

FOR THREE ELEMENT FURNACES WITH

SEPARATE FAN & HEATER LOADS

SINGLE-STAGE Room Thermostat

 

 

 

WIRING

 

M5

M6

To 2nd element

TWO POLE

M7

M8

To 3rd element

 

H

H

To 24vAC wall thermostat

 

M1

M2

To fan

TWO POLE

M3

M4

To 1st element

 

H

H

 

 

 

(Two Timings)

 

 

 

24A34-5

 

TWO-STAGE Room Thermostat Option

 

 

 

WIRING

 

M1

M2

To fan interlock

TWO POLE

M3

M4

To 3rd element

 

H

H To W2 of 24vAC wall thermostat

 

 

(One Timing)

 

 

 

24A34-3 / -4

 

 

M5

M6 To common of 24v transformer

TWO POLE

M7

M8

To 2nd element

 

H

H To W1 of 24vAC wall thermostat

 

M1

M2

To fan

TWO POLE

M3

M4

To 1st element

 

H

H

 

(Two Timings)

24A34-6

2

Page 2
Image 2
White Rodgers 24A34-14, 24A34-2, 24A34-5 Wiring Diagrams, Fan Delay Off, For One Element Furnaces, For Two Element Furnaces