DESCRIPTION
This
Stock Barns
Dairy Barns
Hog Houses Poultry Houses
It has a moisture, vermin and dust resistant enclosure, with the coiled bulb below to prevent collection of foreign matter from impairing sensitivity.
THESE CONTROLS MUST BE INSTALLED BY A QUALIFIED INSTALLER
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and ordinances.
This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.
This control has been accurately calibrated at the factory. Any attempt to calibrate this control will void the White- Rodgers warranty.
PRECAUTIONS
WARNING
Do not use on circuits exceeding specified voltages. Higher voltages will damage control and could cause shock or fire hazard.
CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
|
| SPECIFICATIONS | |
|
| ||
ELECTRICAL DATA | THERMAL DATA | ||
Switch Action: Left Selector – Close on Rise | Range: High Limit - 35° to 110°F (2° to 43°C) | ||
Right Selector – S.P.D.T. |
|
| |
Switch Rating: | Differential: Left Selector - 3°F (1.7°C) Fixed | ||
7.4F.L.A. 44.5L.R.A., 120V.A.C. | Right Selector - 4°F (2.2°C) Fixed | ||
3.7F.L.A. 22.2L.R.A., 240V.A.C. | |||
|
| ||
2.9 Amp., 120/240V.A.C. |
|
|
| |
EMERSON ELECTRIC CO. |
|
9797 REAVIS RD., ST. LOUIS, MO. 63123 |
|
(314) | Printed in U.S.A. |
9999 HWY. 48, MARKHAM, ONT. L3P 3J3 |
|
(905) |
|
PART NO.
Replaces