White Rodgers 259-6 installation instructions White-Rodgers, Temperature Control, Description

Models: 259-6

1 4
Download 4 pages 1.3 Kb
Page 1
Image 1
259-6

259-6

 WHITE-RODGERS WHITE-RODGERS

TEMPERATURE CONTROL

Barn Ventilating

Two Speed Fan Control

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

This Hydraulic-Action temperature control is specifically designed to control the operation of fans in reducing temperature and humidity in such places as:

Stock Barns

Dairy Barns

Hog Houses Poultry Houses

It has a moisture, vermin and dust resistant enclosure, with the coiled bulb below to prevent collection of foreign matter from impairing sensitivity.

THESE CONTROLS MUST BE INSTALLED BY A QUALIFIED INSTALLER

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

This control has been accurately calibrated at the factory. Any attempt to calibrate this control will void the White- Rodgers warranty.

PRECAUTIONS

TEMPERATURE CONTROLWARNING

Do not use on circuits exceeding specified voltages. Higher voltages will damage control and could cause shock or fire hazard.

Barn VentilatingCAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

 

 

SPECIFICATIONS

 

 

ELECTRICAL DATA
THERMAL DATA

Switch Action: Left Selector – Close on Rise

Range: High Limit - 35° to 110°F (2° to 43°C)

Right Selector – S.P.D.T.

 

 

Switch Rating:
Differential: Left Selector - 3°F (1.7°C) Fixed

7.4F.L.A. 44.5L.R.A., 120V.A.C.

Right Selector - 4°F (2.2°C) Fixed

3.7F.L.A. 22.2L.R.A., 240V.A.C.

 

 

2.9 Amp., 120/240V.A.C.

 

 

WHITE-RODGERS DIVISION

 

EMERSON ELECTRIC CO.

 

9797 REAVIS RD., ST. LOUIS, MO. 63123

 

(314) 577-1300, FAX (314) 577-1517

Printed in U.S.A.

9999 HWY. 48, MARKHAM, ONT. L3P 3J3

 

(905) 475-4653, FAX (905) 475-4625

 

PART NO. 37-5567A

Replaces 37-9187 9547

Page 1
Image 1