DESCRIPTION

The 3098-134 and 3098-156 Mercury Flame sensors are designed as universal replacements for types currently used on cycling pilot ignition systems. They will replace sensors used in “thermocouple” type (slip-in) pilot burners. The bulbs on both flame sensors have additional grooves to accept retaining clips (C-rings) allowing them to replace most existing sensors.

The 3098 Flame Sensors are SPDT (single-pole double- throw) devices, with switchcases designed to plug into cycling pilot gas valves. These flame sensors should not be used in appliances other than those listed in the cross reference.

3098 MERCURY FLAME SENSOR

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

!WARNING

Do not use on circuits exceeding specified volt- age. Higher voltage will damage control and could cause shock or fire hazard.

PRECAUTIONS

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Shut off main gas to heating system until installa- tion is complete.

Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dangerous operation.

Following installation or replacement, follow ap- pliance manufacturer's recommended installa- tion and/or service instructions to insure proper operation.

ATTENTION!

This product contains mercury. There will not be any exposure to mercury under normal conditions of use. This product may replace a unit which contains mercury. Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing nonabsorbent gloves, take up the spilled mercury with sand or other absorbent material and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded. Mercury must not be discarded in household trash. When this unit or the unit it is replacing is to be discarded, place in a suitable container and return to us.

WHITE-RODGERS DIVISION

EMERSON ELECTRIC CO.

9797 REAVIS RD., ST. LOUIS, MO. 63123-5398

(314) 577-1300, FAX (314) 577-1517

9999 HWY. 48, MARKHAM, ONT. L3P 3J3

(905) 475-4653, FAX (905) 475-4625

 

PART NO. 37-3600C