White Rodgers 50A55-571 installation instructions Operator Save these instructions for future use

Models: 50A55-474 50A55-571

1 8
Download 8 pages 2.48 Kb
Page 1
Image 1
WHITE-RODGERS

WHITE-RODGERS

50A55-474 & 50A55-571

Integrated Furnace Controls

 

INSTALLATION INSTRUCTIONS

 

 

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

The 50A55-474 and 50A55-571 are automatic gas inter- rupted ignition controls that employ a microprocessor to continually monitor, analyze, and control the proper op- eration of the gas burner, inducer, and fan.

Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation.

These controls incorporate system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction.

PRECAUTIONS

! GENERAL PRECAUTION

Application of this type of control may cause flame rollout on initial start-up and could cause personal injury and/or property damage.

Replace only with exact model number, includ- ing dash number. Failure to use exact replace- ment control could cause personal injury and/or property damage.

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

CONTENTS

 

Description

1

Precautions

1

Specifications

2

Installation

3

Mounting & Wiring

 

Operation

6

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause im- proper and dangerous operation.

This control is not intended for use in locations where it may come in contact with water. Suit- able protection must be provided to shield the control from exposure to water (dripping, spray- ing, rain, etc.).

!WARNING

Do not use on circuits exceeding specified volt- age. Higher voltage will damage control and could cause shock or fire hazard.

Do not short out terminals on gas valve or pri- mary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.

WHITE-RODGERS DIVISION

 

PART NO. 37-5800C

EMERSON ELECTRIC CO.

 

9797 REAVIS ROAD

Printed in U.S.A.

Replaces 37-5800B

ST. LOUIS, MISSOURI 63123-5398

 

9751

Page 1
Image 1
White Rodgers 50A55-571 installation instructions Operator Save these instructions for future use, Description, Contents