White Rodgers 50A66-743 System Component, Terminal, Connection, Typical System Wiring Table, Type

Models: 50A66-743

1 8
Download 8 pages 23.28 Kb
Page 5
Image 5
TYPICAL SYSTEM WIRING TABLE

WIRING

TYPICAL SYSTEM WIRING TABLE

50A66

TERMINAL

SYSTEM COMPONENT

TERMINAL

 

TYPE

 

CONNECTION

W

 

 

 

 

low voltage thermostat W terminal (or equivalent)

G

Terminal

 

low voltage thermostat G terminal (or equivalent)

R

block with

 

low voltage thermostat R terminal (or equivalent)

Y

captive

 

low voltage thermostat Y terminal (or equivalent)

 

screws

 

 

(2nd wire from Y terminal goes to 24 VAC HOT side of

 

 

 

 

 

compressor contactor coil)

C

 

 

 

 

24 VAC COMMON side of compressor contactor coil

HLO (Pin 1)

 

 

 

 

high limit OUTPUT

Not Used (Pin 2)

 

 

 

 

 

TH (Pin 3)

 

 

 

 

24 VAC transformer (low voltage HIGH side)

Not Used (Pin 4)

HLO

PSO

HLI

PSI

 

RO1 (Pin 5)

rollout switch OUTPUT

 

 

 

 

TR (Pin 6)

MV

RO

GND

RO

24 VAC transformer (low voltage COMMON side)

LO

OUT

OUT

 

 

 

 

HLI (Pin 7)

TH

TR

COM

MV

high limit INPUT

 

 

 

MV

 

 

GND (Pin 8)

 

 

 

 

MUST BE RELIABLY GROUNDED TO CHASSIS

MV COM (Pin 9)

 

 

 

 

gas valve COMMON

PSI (Pin 10)

 

 

 

 

pressure switch INPUT

RO2 (Pin 11)

 

 

 

 

rollout switch INPUT

MV (Pin 12)

 

 

 

 

gas valve

IND

 

 

 

 

inducer HOT side

IGN

IND

IGN

IND

IGN

ignitor HOT side

IND N

N

N

 

 

 

inducer NEUTRAL side

 

 

 

 

IGN N

 

 

 

 

ignitor NEUTRAL side

COOL

1/4” spade terminal

circulator blower COOL SPEED terminal

HEAT

1/4” spade terminal

circulator blower HEAT SPEED terminal

PARK (3 terminals)

1/4” spade terminal

unused circulator blower terminals

LINE

1/4” spade terminal

input voltage (120 VAC) HOT side

XFMR

1/4” spade terminal

24 VAC transformer line voltage HOT side

EAC (optional)

1/4” spade terminal

electronic air cleaner HOT side

HUM (optional)

1/4” spade terminal

humidifier HOT side

120 VOLT NEUTRAL

1/4” spade terminal

Terminals for 120 Volt NEUTRAL for line, transformer,

(5 terminals)

 

 

 

 

circulator, electronic air cleaner and humidifier

FP (E33)

3/16” spade terminal

flame sensor probe*

FAN

1/4” spade terminal

Circulator blower fan speed terminal

24 V HUM (E2)

1/4” receptacle

 

24 VAC humidifier

* maximum recommended flame probe wire length is 36 inches.

5

Page 5
Image 5
White Rodgers 50A66-743 installation instructions System Component, Terminal, Connection, Typical System Wiring Table, Type