White Rodgers 755-1 installation instructions 754-1, White-Rodgers, Electric Water Heater Control

Models: 756-1 755-1 754-1

1 6
Download 6 pages 22.79 Kb
Page 1
Image 1
754-1, 755-1, 756-1

754-1, 755-1, 756-1

WHITE-RODGERS

Electric Water Heater Control

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

This control is designed to meet the high electrical capac- ity requirements of electric water heaters.

The temperature control is a normally closed switch which opens on a rise in temperature. The SPST version (755-1) will control one heating element. The SPDT version (756-1) will control two heating elements when used with W-R type 755-1. (See wiring diagrams.)

DESCRIPTION

The limit control (754-1) is a normally closed DPST switch which opens on a rise in temperature to limit the maximum allowable temperature. It has manual reset.

Both switches are calibrated to meet the requirements for typical residential type storage tank water heaters.

THIS CONTROL MUST BE INSTALLED BY A QUALI- FIED INSTALLER.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

This control has been accurately calibrated at the factory. Any attempt to re-calibrate this control will void the White- Rodgers warranty.

!WARNING

Do not use on circuits exceeding specified volt- ages. Higher voltages will damage control and could cause shock or fire hazard.

If in doubt about whether your wiring is millivolt, low or line voltage, have it inspected by a quali- fied heating and air conditioning contractor or a licensed electrician.

PRECAUTIONS

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dangerous operation.

Following installation or replacement, follow appliance manufacturers’ recommended instal- lation/service instructions to insure proper op- eration.

WHITE-RODGERS DIVISION

EMERSON ELECTRIC CO.

9797 REAVIS ROAD

ST. LOUIS, MISSOURI 63123-5398

PART NO. 37-5787A

Printed in U.S.A.