White Rodgers 829A-845 specifications Wiring Cont, Diagram For Boiler With Tankless Domestic Coil

Models: 829A-845

1 6
Download 6 pages 62.85 Kb
Page 3
Image 3
WIRING CONT.

WIRING CONT.

DIAGRAM FOR BOILER WITH TANKLESS DOMESTIC COIL

 

 

24 VAC

Fig. 5a & 6a Diagram for

 

 

GAS VALVE

 

HIGH LIMIT

Gas-Fired System

 

 

 

 

 

 

TRANS.

 

 

TYPE 668 OIL

 

 

TYPE 668 OIL

 

 

BURNER CONTROL

BURNER CONTROL

 

 

 

 

 

THERMOSTAT

 

(LINE VOLTAGE)

 

 

THERMOSTAT

 

(LINE VOLTAGE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

IGNITION

 

HOT

LINE

 

 

IGNITION

 

HOT

LINE

N

 

 

 

 

 

TRANS.

 

 

 

TRANS.

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

T

 

X

X

 

 

 

T

T

 

X

X

BURNER

 

 

BURNER

 

1

2

 

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

3

 

4

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

CIRCULATOR

 

5

 

 

 

 

CIRCULATOR

 

 

 

 

 

 

MOTOR

 

 

 

6

 

 

MOTOR

 

 

 

6

 

 

 

 

 

 

 

 

FIELD

 

 

 

 

 

 

 

FIELD

 

 

 

 

 

 

INSTALLED

 

 

 

 

 

 

INSTALLED

 

 

HIGH

LOW

CIRCULATOR

JUMPERS

 

 

HIGH

TYPE

LOW

TYPE 11B05

JUMPERS

 

 

 

 

 

 

 

 

CONTROL

LIMIT

CONTROL

 

 

 

 

LIMIT

11B30

LIMIT

CIRCULATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

Fig. 5 Diagram for System using High Limit-Low Limit control and Circulator control.

Fig. 6 Diagram for System using High Limit control and Low Limit-Circulator control.

The low limit control maintains domestic hot water at desired temperature year-round.

When the thermostat calls for heat, the burner starts. The circulator also starts if boiler temperature is above setting of circulator control.

If excessive boiler temperature causes high limit to open,

the circulator continues to run but the burner shuts down until the high limit recloses.

When low boiler temperature causes the circulator control to open, burner stays on but the circulator stops until the circulator control recloses. When thermostat is satisfied, the circulator stops. The burner also shuts down if boiler temperature is above setting of low limit control.

DIAGRAM FOR MULTIZONE HYDRONIC HEATING SYSTEM

THERMOSTAT

THERMOSTATZONE 1

ZONE 2

 

 

 

T

 

 

 

T

T T

 

 

ZC

1

 

 

 

 

2

 

ZR

 

 

 

3

 

 

 

JUMPER

4

 

B1

 

 

 

 

 

 

 

*CIRCULATOR

B2

5

6

ZONE 2

 

 

 

C1

 

 

 

 

 

 

C2

 

 

 

1

Fig. 7

 

 

2

 

 

 

TO ADDITIONAL 829A-845 RELAYS

FOR OTHER ZONES

TO BURNER

TO CIRCULATOR ZONE 1

DIAGRAM FOR BOILER WITH TANKLESS DOMESTIC COILHOT

LINE

N

*Terminal No. 4 or No. 6 may go to zone 2,

The other terminal then goes to ZR.

3

Page 3
Image 3
White Rodgers 829A-845 specifications Wiring Cont, Diagram For Boiler With Tankless Domestic Coil