Basic Test Procedure

www.ti.com

2.2.5Register Control

Send All: Sends the register configuration to all devices

Read All: Reads register configuration from DAC348x device

Load Regs: Load a register file for all devices. Sample configuration files for common frequency plans are located in the install directory.

O Select Load Regs button.

O Double click on the data folder.

O Double click on the desired register file.

OClick on Send All to ensure all of the values are loaded properly.

Save Regs: Saves the register configuration for all devices

2.2.6Miscellaneous Settings

Reset USB: Toggle this button if the USB port is not responding. This generates a new USB handle address

ONote: It is recommended that the board be reset after every power cycle and the “reset usb” button on the GUI be clicked.

Exit: Stops the program

3Basic Test Procedure

This section outlines the basic test procedure for testing the EVM.

3.1Test Block Diagram

The test set-up for general testing of the DAC348x with the TSW3100 pattern generation card is shown in Figure 7.

 

 

PC

 

 

 

Ethernet

 

 

USB

Cross-over

EthernetCable

+5V

USBMini-B

Cable

 

 

 

 

 

J13

J9

J9

J14

 

 

J74

J13

 

 

TSW3100

DAC348X

RF

 

 

 

 

 

 

Pattern

 

 

 

Generator

 

LO

 

 

 

J18

 

 

 

 

+6 V

Signal

Generator

(CLK Source)

Spectrum

Analyzer

Signal

Generator

(LO Source)

Figure 7. Test Set-up Block Diagram

8

DAC3484/DAC3482 EVM

SLAU336 –March 2011

 

 

Submit Documentation Feedback

© 2011, Texas Instruments Incorporated

Page 8
Image 8
Texas Instruments DAC3482, DAC3484 installation instructions Test Block Diagram, Register Control, Miscellaneous Settings