OZONE REDUCTION
All electronic air cleaners typically produce a small amount of ozone that is within established limits. Some customers may notice an odor especially at high altitudes or low air flow rates.
This power supply has a “hairpin” shaped jumper wire labeled W1 (see Fig 24) that can be cut and separated in case of such complaints. This will cause the power supply to limit the maximum operating power to a lower level.
W1
Cut and separate
Ozone Reduction
Jumper
WHT/BRN |
| BLK | |||||||
|
|
|
|
|
|
|
| ||
E3 | LINE | E2 | |||||||
|
|
|
|
|
|
|
|
|
Ozone Reduction Jumper
Figure 24
ELECTRONIC AIR CLEANER RETROFIT (ACR) KITS
INSTALLATION
1.Remove the two
2.Insert the two collecting cells into the cabinet behind the
3.Remove cover plate on the power supply junction box and remove the knockout needed to bring the wire to the female receptacle.
4.Position receptacle with ground in the down position as shown in Fig 17 (page 7) and pull wires through the receptacle locator on the junction box. Snap the receptacle into the hole until secure.
5.Connect ground wire from receptacle and ground wire in kit to cabinet with rivet and washer as follows:
a)Place washer on rivet
b)Place terminal from ground wire on rivet
c)Place terminal from receptacle ground wire on rivet
d)Insert rivet in hole in junction box and secure.
WIRING
5.For wiring installation (see page 7) and follow all wiring instructions 7, 8 and 9.
6.Install the power pack (see page 7) instruction 11.
7.For operation (see page 8 – Operation).
Cabinet | |
Handle |
Contact
Button
Collecting Cells | Contact |
| Button |
13