![TROUBLESHOOTING](/images/new-backgrounds/72353/7235317x1.webp)
∙Dirt from the condenser should be cleaned by a qualified technician when necessary.
TROUBLESHOOTING
Problem | Cause | Solution |
The compressor runs for | The voltage is not in the | Switch off the power |
1 to 5 minutes and | correct range. | and restart when the |
stops. |
| power is normal. |
| The refrigerant has |
|
The compressor runs | leaked. | Contact service |
but the inner liner does |
| department via email at |
not get cold. |
| service@whynter.com |
The system is blocked. | ||
| The ice layer on the | Defrost the freezer |
| evaporator is too thick. |
|
| The door is being opened | The door should be |
| and closed too | opened as little as |
The inner liner is very | frequently. | possible. |
cold and the | The freezer is | Remove some products |
compressor runs | overloaded. | from the freezer. |
continuously. | The condenser is not | Place the freezer in a |
| ||
| The temperature sensor- | Contact service |
| tube is out of the | department via email at |
| evaporator or the | service@whynter.com |
| controller is faulty. |
|
| The controller is faulty | Contact service |
| (the power indicator is | department via email at |
The compressor does | not on). | service@whynter.com |
not run. | The thermostat is set too |
|
| high and the ambient | Set the freezer to a |
| temperature is too low. | lower temperature. |
The freezer is noisy. | The freezer is not level. | Place the freezer on a |
|
| flat and hard surface. |
| The voltage is not in the | Switch off the power |
| correct range.. | and restart when the |
|
| power is normal. |
9