![TROUBLESHOOTING](/images/new-backgrounds/72362/7236219x1.webp)
TROUBLESHOOTING
Problem | Possible Causes | Solutions |
|
|
|
∙ The compressor works ab- | ∙ The voltage is lower than rec- | ∙ Stop the ice maker and do not restart until |
normally with a buzzing | ommended | the voltage is normal |
noise |
|
|
|
|
|
∙ Water shortage indicator light | ∙ There is not enough water in | ∙ Press the ON/OFF button, fill with water, |
is on | the reservoir | wait 3 minutes and press the power button |
|
| again to restart |
|
|
|
∙ Ice full indicator light is on | ∙ Ice basket is full to the top | ∙ Remove some of the ice |
|
|
|
∙ Indicator lights are off | ∙ Blown fuse/ no power/blown | ∙ Replace fuse / turn power on |
| breaker |
|
|
|
|
∙ The ice made is too large | ∙ The water temperature in the | ∙ Stop the machine and reset the ice |
and with pieces sticking to- | storage tray or ambient is too | making cycle |
gether | low |
|
|
| ∙ Restart the machine after |
|
| turning it off |
|
|
|
∙ Ice appears cloudy | ∙ Due to fast freezing, ice cubes | ∙ This is normal |
| may appear "cloudy", this is |
|
| trapped air in the water and |
|
| does not affect the taste or |
|
| quality of the ice. |
|
|
|
|
∙ Not all freezing bars makes | ∙ Amount of water in the reser- | ∙ Make sure that water is at MAX level be- |
ice | voir is insufficient | fore using the portable ice maker |
| ∙ No water in the reservoir | ∙ Run the unit for a couple more cycles and |
|
| all bars should be frozen |
| ∙ When the unit is first started, |
|
| refrigerant may not be flowing |
|
| to all freezing bars |
|
|
|
|
∙ Ice full indicator is on but ice | ∙ Ice Full sensor is obstructed | ∙ Make sure that there are no obstruction or |
is not full |
| objects aligned with the ice full sensor |
| ∙ Build up form on the sensor | ∙ Remove the ice cubes from the ice basket |
|
| |
|
| and close the ice maker cover |
|
| ∙ Use a mild vinegar solution to clean the |
|
| sensor |
|
|
|
∙ Conditions for ice making | ∙ Refrigerant leaks/ sealed sys- | ∙ Contact Whynter Service Department |
cycle are right but no ice is | tem is blocked |
|
made |
|
|
|
|
|
10